Description: Printmech: 42V to Paper motor failure
Causes: The 42V cable from Printmech to Paper motor has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to paper motor cable. 2. Check the paper motor. 3. Check the Printmech PCA.
Causes: The 42V cable from Printmech to Rewinder has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Rewinder cable. 2. Check the Rewinder. 3. Check the Printmech PCA.
Causes: The 42V cable from Printmech to Scan motor has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Scan motor cable. 2. Check the Scan motor. 3. Check the Printmech PCA.
Description: Printmech: 42V to SOL slit solenoid failure
Causes: The 42V cable from Printmech to SOL slit solenoid has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to SOL slit solenoid cable. 2. Check the slit solenoid. 3. Check the Printmech PCA.
Description: The 12V provided from Printmech to Curing module PCA are out of range (10,8V to 13,2V)
Causes: One or more of the components powered by the 12V at the Curing Control PCA are causing a short circuit. The 12V cable from Printmech to the Curing Control PCA has a problem.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to the Curing module PCA. 2. Check the Printmech PCA.