Description: Printmech: 42V to SOL slit solenoid open circuit
Causes: The 42V cable from Printmech to SOL slit solenoid has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to SOL slit solenoid cable. 2. Check the slit solenoid. 3. Check the Printmech PCA.
Causes: The 5V cable from Printmech to PSU has a problem Printmech PCA is damaged PSU is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that DS7 Printmech LED is turned on. If it is not the case, replace the Printmech PCA. 2. If the problem persist, replace the PSU.
Description: Printmech: 12V to ISS, DD, 42Vdc motor drivers, Top cover fans and PZ fans failure
Causes: The 12V cable from Printmech to ISS, Interconnect and PZ fans has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cables to the ISS, Interconnect and PZ fans. 2. Check the Printmech PCA.
Description: Printmech: Hannibal1 24V failure. Check APS relief valve, SVS motor and Rack engage motor
Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the APS relief valve, SVS motor and Rack engage motor. 2. Check the Printmech PCA.