Description: Curing System unable to warm up in the pre-defined amount of time
Causes: Ambient temperature below 15oC. Low AC Voltage. Fans (Curing, Air Curtain, PZ). Curing Resistors. Curing Temperature Sensor. Curing Pressure Sensor.
Remedy: 1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check if the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor". 4. Check all Fans (Curing, Air Curtain, PZ), all spinning and no obstruction. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.02:00
Description: Curing system: cool down timeout
Causes: Ambient temperature above 30C Fans (Curing, Air Curtain, PZ).
Remedy: Service engineer: 1. The environmental ambient temperature is too hot or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters etc. 2. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
Code: 16.03:00
Description: Curing system: high temperature error
Causes: Ambient temperature above 30oC, Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy: 1. The environmental ambient temperature is too hot or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters etc. 2. Run Service "Curing system monitor”. 3. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 4. Reseat/Replace Curing Resistors. 5. Reseat/Replace Curing Temperature Sensors. 6. Reseat/Replace Curing Pressure Sensor.
Code: 16.04:00
Description: Curing system: low temperature error
Causes: Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy: 1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor. 4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.05:00
Description: Curing system: temperature sensor error
Causes: Curing Control PCA Temperature Sensors Cable Temp. Sensors.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/replace Curing Control PCA Temperature Sensors Cable. 3. Reseat/replace Temp. Sensors.
Code: 16.07:03
Description: Curing system: warm up timeout (uniformity)
Causes: Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy: 1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor. 4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.11:10
Description: Curing System: Temperature sensor 1 failure or not connected
Causes: Curing Control PCA Sensors cable Temp. sensor 1.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Reseat/replace Curing Control Sensors cable. 2. Reseat/replace Temp. sensor 1.