Description: Air Curtain system: Box fan fault or disconnected
Causes: Air Curtain Box Fan, Air Curtain and Printzone Heaters Control PCA.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Reseat/replace Air Curtain Box Fan. 2. Replace Air Curtain and Printzone Heaters Control PCA.
Code: 16.71:10
Description: Air Curtain system: Board box fan or cable damaged
Causes: Board box fan or cable damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Reseat/replace Air Curtain Box Fan. 2. Replace Air Curtain and Printzone Heaters Control PCA.
Code: 16.82:11
Description: Air Curtain steady resistor:Not connected
Causes: Air Curtain and Printzone Heaters Control to Curing Power Interconnect PCA Cables, Air Curtain Steady Resistor.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control to Curing Power Interconnect PCA cables. 2. Reseat/Replace Air Curtain Resistors.
Code: 16.83:11
Description: Vapor burst resistor: Not connected
Causes: Air Curtain and Printzone Heaters Control to Curing Power Interconnect PCA Cables, Air Curtain Burst Resistor.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control to Curing Power Interconnect PCA cables. 2. Reseat/Replace Vapor Resistors.
Code: 16.84:03
Description: Air Curtain steady resistor: Out of range
Causes: Air Curtain Resistors.
Remedy: Call agent: • Restart the printer. Service engineer: • Reseat/Replace Air Curtain Resistors.
Code: 16.85:03
Description: Air Curtain burst resistor: Out of range
Causes: Air Curtain Resistors.
Remedy: Call agent: • Restart the printer. Service engineer: • Reseat/Replace Air Curtain Resistors.
Code: 16.90:10
Description: Air Curtain: Temperature sensor failure or not conected
Causes: Air Curtain and Printzone Heaters Control/Curing Control PCA (depending on SKU) to Air Curtain Temperature Sensor Cable, Air Curtain Temperature Sensor.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control/Curing Control PCA to Air Curtain Temperature Sensor Cable. 2. Replace Air Curtain Temperature Sensor.
Code: 17.0:11
Description: PrintMech to Interconnect Power cable does not seem to be connected
Causes: The power cable from Printmech to Interconnect PCA has a problem.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the PrintMech to Interconnect Power cable is not damaged. 2. Check that the PrintMech to Interconnect Power cable is correctly connected to the PrintMech PCA and the Interconnect PCA. 3. Replace the PrintMech to Interconnect Power cable (which is included in the Electronics Module Cable Kit).