Code :
- Code: CEEE2
- Description: Scanner section malfunction. A scanner part is faulty.
- Causes: • LED exposure unit • CCD unit • CCD board (CCDB)
- Remedy: 1. Check the connectors on CCDB for proper connection and correct as necessary. 2. Replace the LED exposure unit. 3. Replace the CCD unit.
- Code: CF0xx
- Description: An exceptional instance occurred due to the unexpected parameter in the system F/W.
- Causes: MFP board (MFPB)
- Remedy:
- Code: CF1xx
- Description: Compression malfunctions
- Causes: MFP board (MFPB)
- Remedy:
- Code: CF2xx
- Description: An exceptional instance occurred due to the unexpected parameter in the system F/W.
- Causes: MFP board (MFPB)
- Remedy:
- Code: CF3xx
- Description: Image transfer error on IR input bus
- Causes: MFP board (MFPB)
- Remedy:
- Code: CF4xx
- Description: Communication error (between IR-systems)
- Causes: MFP board (MFPB)
- Remedy:
- Code: CF5xx
- Description: Communication error (IR detected)
- Causes: MFP board (MFPB)
- Remedy:
- Code: CF6xx
- Description: An exceptional instance occurred due to the unexpected parameter in the system F/W.
- Causes: • MFP board (MFPB) • Engine
- Remedy: