Description: Tray 4 lift-up failure (When PC-213 is installed) The tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Causes: • Tray 4 lift-up motor (M123) • Tray 4 upper limit sensor (PS126) • PC control board (PCCB) • MFP board (MFPB)
Remedy: 1. Check the connector between M123-PCCB CN8 for proper connection and correct as necessary. 2. Check the connector of M123 for proper drive coupling and correct as necessary. 3. Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary. 4. PS126 I/O check, sensor check • Control signal: PCCB CN7-3 (ON) • Location of electrical component: PC-213 8-K 5. M123 operation check • Control signal: PCCB CN8-8 to 9 • Location of electrical component: PC-213 5-K 6. Replace M123. 7. Replace PCCB. 8. MFPB F4E conduction check 9. Replace MFPB. NOTICE • Link to the wiring diagram (N.2.3 PC-213)
Code: C0210
Description: LCT lift failure (When PC-413 is installed) • The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. • The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operating. • The main tray upper limit sensor (PS136) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-down operation began. • The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-down operation began.
Causes: • Elevator motor (M134) • Main tray upper limit sensor (PS136) • Shifter stop / lower limit position sensor (PS138) • PC control board (PCCB) • MFP board (MFPB)
Remedy: 1. Check the connector between M134-PCCB CN10 for proper connection and correct as necessary. 2. Check the connector of M134 for proper drive coupling and correct as necessary. 3. Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary. 4. Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary. 5. PS136 I/O check, sensor check • Control signal: PCCB CN4-3 (ON) • Location of electrical component: PC-413 8-J 6. PS138 I/O check, sensor check • Control signal: PCCB CN14-6 (ON) • Location of electrical component: PC-413 4-J 7. M134 operation check • Control signal: PCCB CN10-1 to 2 • Location of electrical component: PC-413 6-J 8. Replace M134. 9. Replace PCCB. 10. MFPB F4E conduction check 11. Replace MFPB.
Code: C0211
Description: Manual feed up/down abnormality • Paper is not turned OFF (unblock) the bypass tray position sensor (PS28) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The bypass tray position sensor (PS28) is not turned ON (blocked) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position
Causes: • Transport motor (M1) • Bypass pick-up solenoid (SD1) • Bypass tray position sensor (PS28) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN19E for proper connection and correct as necessary. 2. Check the connector of M1 for proper drive coupling and correct as necessary. 3. Check the connector between PS28-relay CN91 (bizhub 367), CN34 (bizhub 287), CN90 (bizhub 227)-MFPB CN9 for proper connection and correct as necessary. 4. SD1-relay CN41- relay CN91 (bizhub 367), CN34 (bizhub 287), CN90 (bizhub 227)-MFPB CN9E for proper connection and correct as necessary. 5. PS28 I/O check, sensor check • Control signal: MFPB CN9E-3 (ON) • Location of electrical component: 3-J 6. SD1 operation check • Control signal: MFPB CN9E-12 (ON) • Location of electrical component: 4-J 7. M1 operation check • Control signal: MFPB CN19E-3 to 7 • Location of electrical component: 26-C 8. Replace M1. 9. MFPB F5E conduction check 10. Replace MFPB.
Code: C0214
Description: LCT shift failure (When PC-413 is installed) • The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter home sensor (PS139) is not turned OFF (unblocked) even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the return operation began (shift to the left). • The shifter home sensor (PS139) is not turned ON (blocked) even after the set period of time has elapsed after the return operation began (shift to the left).
Causes: • Shifter motor (M133) • Shifter stop / lower limit position sensor (PS138) • Shifter home sensor (PS139) • PC control board (PCCB)
Remedy: 1. Check the connector between M133-PCCB CN10 for proper connection and correct as necessary. 2. Check the connector of M133 for proper drive coupling and correct as necessary. 3. Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary. 4. Check the connector between PS139-relay CN16-PCCB CN14 for proper connection and correct as necessary. 5. PS138 I/O check, sensor check • Control signal: PCCB CN14-6 (ON) • Location of electrical component: PC-413 4-J 6. PS139 I/O check, sensor check • Control signal: PCCB CN14-3 (ON) • Location of electrical component: PC-413 4-J 7. M133 operation check • Control signal: PCCB CN10-3 to 4 • Location of electrical component: PC-413 6-J 8. Replace M133. 9. Replace PCCB.
Code: C1004
Description: FNS communication error (When FS-533, FS-534, FS-534SD or JS-506 is installed) <When FS-533, FS-534 or FS-534SD is installed> • When the FS control board (FSCB) is receiving data, a communication error is detected.
Causes: <When FS-533, FS-534 or FS-534SD is installed> • FS control board (FSCB) <When JS-506 is installed> • JS control board (JSCB)
Remedy: (a) When FS-533, FS-534 or FS-534SD is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace FSCB. (FS-533/FS-534/FS-534SD) (b) When JS-506 is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace JSCB.
Code: C1081
Description: SD communication error (When FS-534SD is installed) When a communication error is detected between the FS control board (FSCB) and the SD control board (SDDB).
Remedy: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace SDDB. 4. Replace FSCB.
Code: C1102
Description: Main tray up/down motor drive malfunction (When FS-533, FS-534 or FS-534SD is installed) <When FS-533 is installed> • While the exit tray is being lifted, the paper exit tray home sensor (PS107) is not turned OFF (unblocked) after the set period of time has elapsed after the tray lift up motor (M109) is turned ON. • While the exit tray is being lowered, the paper exit tray home sensor (PS107) is not turned ON (blocked) after the set period of time has elapsed after the tray lift up motor (M109) is turned ON. <When FS-534 or FS-534SD is installed> • While the exit tray is being lifted, the main tray upper position sensor (PS26/PS27) is not turned ON (blocked) and the main tray upper position detect switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by the set number of times. • While the exit tray is being lowered, the main tray full detection sensor (PS29) is not turned ON (blocked) after the set period of time has elapsed after the main tray up/down motor (M11) is turned ON.
Causes: <When FS-533 is installed> • Tray lift up motor (M109) • Paper exit tray home sensor (PS107) • FS control board (FSCB) <When FS-534 or FS-534SD is installed> • Main tray up/down motor (M11) • Main tray upper position sensor/R (PS26) • Main tray upper position sensor/F (PS27) • Main tray full detection sensor (PS29) • Main tray upper position detect switch (SW2) • FS control board (FSCB)
Remedy: (a) When FS-533 is installed 1. Check the connector between M109-FSCB CN108 for proper connection and correct as necessary. 2. Check the connector of M109 for proper drive coupling, and correct as necessary. 3. Check the connector between PS107-FSCB CN110 for proper connection and correct as necessary. 4. PS107 I/O check, sensor check • Control signal: FSCB CN110 • Location of electrical component: FS-533 7-D to E 5. M109 operation check • Control signal: FSCB CN108 • Location of electrical component: FS-533 10-E 6. Replace M109. 7. FSCB CP109 conduction check 8. Replace FSCB. NOTICE • Link to the wiring diagram (N.2.5 FS-533) (b) When FS-534 or FS-534SD is installed 1. Check the motor, sensor and switch connectors for proper connection, and correct as necessary. 2. Check the connector of M11 for proper drive coupling, and correct as necessary. 3. PS26 I/O check, sensor check • Control signal: FSCB J14<A>-5 (ON) • Location of electrical component: FS-534 2-C 4. PS27 I/O check, sensor check • Control signal: FSCB J14<B>-8 (ON) • Location of electrical component: FS-534 3-C 5. PS29 I/O check, sensor check • Control signal: FSCB J14<A>-8 (ON) • Location of electrical component: FS-534 4-C 6. SW2 operation check • Control signal: FSCB J10-1 to 2 • Location of electrical component: FS-534 8-K 7. M11 operation check • Control signal: FSCB J9<A>-9 to 10 • Location of electrical component: FS-534 10-C to D 8. Replace M11. 9. Replace FSCB.
Code: C1103
Description: Alignment plate motor/Fr malfunction (When FS-533, FS-534 or FS-534SD is installed) <When FS-533 is installed> • The alignment plate home sensor/F (PS108) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate home sensor/F (PS108) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/F (M105) is turned ON to return the plate to the home position. <When FS-534 or FS-534SD is installed> • The alignment plate/F home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. • The alignment plate/F home sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Front (M7) is turned ON to return the plate to the home position. • The alignment plate/F does not reach the specified position within the set period of time.
Causes: <When FS-533 is installed> • Alignment motor/F (M105) • Alignment plate home sensor/F (PS108) • FS control board (FSCB) <When FS-534 or FS-534SD is installed> • Alignment motor/Front (M7) • Alignment plate/F home sensor (PS12) • FS control board (FSCB)
Remedy: (a) When FS-533 is installed 1. Check the connector between M105-FSCB CN102 for proper connection and correct as necessary. 2. Check the connector of M105 for proper drive coupling, and correct as necessary. 3. Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary. 4. PS108 I/O check, sensor check • Control signal: FSCB CN102 • Location of electrical component: FS-533 7-J 5. M105 operation check • Control signal: FSCB CN102 • Location of electrical component: FS-533 7-J 6. Replace M105. 7. FSCB CP105 conduction check 8. Replace FSCB. NOTICE • Link to the wiring diagram (N.2.5 FS-533) (b) When FS-534 or FS-534SD is installed 1. Check the connector between M7-FSCB J4 for proper connection and correct as necessary. 2. Check the connector of M7 for proper drive coupling and correct as necessary. 3. Check the connector between PS12-FSCB J4 for proper connection and correct as necessary. 4. PS12 I/O check, sensor check • Control signal: FSCB J4<B>-4 (ON) • Location of electrical component: FS-534 13-C 5. M7 operation check • Control signal: FSCB J4<A>-5 to 8 • Location of electrical component: FS-534 11-C to D 6. Replace M7. 7. Replace FSCB.