Description: TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall developing unit. 3 Reinstall toner bottle. 4 Check the contact of developing unit for proper connection and correct as necessary. 5 Check the connector between TCRSB CN29-relay CN28-PRCB CN24 for proper connection and correct as necessary. 6 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 7 Check the connector between M4-relay CN13-PRCB CN8 for proper connection and correct as necessary. 8 M3 operation check. 9 M4 operation check. 10 Change developing unit. 11 Change TCRSB. 12 Change PRCB.
Description: TCR sensor failure
• Alarm signals for a TCR sensor are detected. This detection is used for detecting disconnection of TCR sensor board (TCRSB) connector.
Remedy: 1 Reinstall developing unit. 3 Reinstall toner bottle. 4 Check the contact of developing unit for proper connection and correct as necessary. 5 Check the connector between TCRSB CN29-relay CN28-PRCB CN24 for proper connection and correct as necessary. 6 Check the connector between M3-PRCB CN8 for proper connection and correct as necessary. 7 Check the connector between M4-relay CN13-PRCB CN8 for proper connection and correct as necessary. 8 M3 operation check. 9 M4 operation check. 10 Change developing unit. 11 Change TCRSB. 12 Change PRCB.
Description: Main backup media access error
• When an error is detected at the data reading process. • The machine writes and reads data, and judges that the data has error. Then the machine performs the same process and judges again that the data has error. • When counter values are read, error is detected. • The machine detects that it does not have EEPROM.
Remedy: 1 Reboot the machine. 2 Check the EEPROM on the PRCB for proper connection and correct as necessary. 3 Change PRCB. 4 Change EEPROM.
Description: Fusing heaters trouble (center)
• Detected temperature of the heating roller thermistor (TH2; center) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit. 6 Change PRCB. 7 Change DCPU.
Description: Fusing heaters trouble (edge)
• Detected temperature of the heating roller thermistor (TH2; edge) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit. 6 Change PRCB. 7 Change DCPU.
Description: Fusing abnormally high temperature detection (center)
• Detected temperature of the heating roller thermistor (TH2; center) goes beyond a given temperature for a given period of time consecutively.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Fusing abnormally high temperature detection (edge)
• Detected temperature of the heating roller thermistor (TH2; edge) goes beyond a given temperature for a given period of time consecutively.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Fusing abnormally low temperature detection (center)
• Detected temperature of the heating roller thermistor (TH2; center) goes below a given temperature for a given period of time consecutively after warm up is completed.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.