Description: Scanner sequence trouble 1
• The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in ADF.
Remedy: 1 Correct the harness connection between main body and ADF if faulty. 2 Change REYB/SCAN. 3 Change DFCB. 4 Change MFPB.
Description: Before reading pressure welding alienation mechanism
• During a pressure motion being performed, the reading roller release position sensor (PS12) output does not change from H to L. • During a retraction motion being performed, the reading roller release position sensor (PS12) output does not change from L to H.
Remedy: 1 Check the connector between M3-relay CN5-DFCB J15 for proper connection and correct as necessary. 2 Check the connector between PS12-DFCB J15 for proper connection and correct as necessary. 3 Check the connector of M3 for proper drive coupling, and correct as necessary. 4 PS12 I/O check, sensor check. 5 M3 operation check. 6 Change M3. 7 DFCB F8 conduction check. 8 Change FSCB.
Description: Glass cleaning mechanism trouble
• The glass cleaning roller home sensor (PS13) is not turned ON after the set period of time has elapsed after the glass cleaning motor (M4) is turned ON.
Remedy: 1 Check the connector between M4-DFCB J1 for proper connection and correct as necessary. 2 Check the connector between PS13-DFCB J8 for proper connection and correct as necessary. 3 Check the connector of M4 for proper drive coupling, and correct as necessary. 4 PS13 I/O check, sensor check. 5 M4 operation check. 6 Change M4. 7 DFCB F1 conduction check. 8 Change DFCB.
Description: Cooling fan trouble
• The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is spinning
Remedy: 1 Check the connector between FM1-DFCB J13 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check. 4 Change FM1. 5 DFCB F7 conduction check. 6 Change DFCB.
Description: Exposure turning on the lamp trouble detection
• The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.
Remedy: 1 Check the connection between the lamp harness and the inverter board, and correct if necessary. 2 Check the connector between INVB CN1- REYB/SCAN PJ7 for proper connection and correct as necessary. 3 Check the connector between REYB/ SCAN PJ2-MFPB PJ14 for proper connection and correct as necessary. 4 Check the connector between CCDB PJ2- MFPB PJ01 for proper connection and correct as necessary. 5 Change INVB. 6 Change exposure unit. 7 Change CCDB. 8 Change REYB/SCAN.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.