Description: Failed to arrive home
• Error of the imaging carriage home sensor. • Error of the carriage motor.
Causes: • Controller board (CTLB) • Imaging carriage home sensor (PS15) • Flatbed motor (M4)
Remedy: 1 Turn OFF/ON the main power switch. 2 Check CTLB for proper connection and correct as necessary. 3 Check PS15 and M4 for proper connection and correct as necessary. 4 Replace Flatbed unit. 5 Replace ADF unit. 6 Replace CTLB.
Code: 9401
Description: Exposure lamp lighting failure detected
The intensity of the lamp is not stabilized within a predetermined period of time during the lamp stabilization check process in a lamp warm-up cycle.
Causes: • Controller board (CTLB) • Scanner unit
Remedy: 1 Check the connector between scanner unit-CTLB J101 for proper connection and correct as necessary. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. 5 Replace scanner unit 6 Replace CTLB
Code: B001
Description: FAX board error 1
Causes:
Remedy:
Code: B002
Description: FAX board error 2
Causes:
Remedy:
Code: B003
Description: FAX board error 3
Causes:
Remedy:
Code: B051
Description: FAX board mount failure line 1
Causes:
Remedy:
Code: B110
Description: Instance generation error or observer registration error
Causes:
Remedy:
Code: B111
Description: Configuration space initialization NG