Code: 4501-111.63

Description: Laser malfunction
Timed out on reboot sweep.
Causes: • Printhead (PH) • Controller board (CTLB)
Remedy: 1 Check PH cables JLSU1 and J6 for proper connection. Reseat the cables if any abnormality is found. 2 Inspect PH cables and connectors. 3 Replace CTLB. 4 Replace PH.

Code: 4501-111.64

Description: Laser malfunction
Attempted to exceed open loop drive limits.
Causes: • Printhead (PH) • Controller board (CTLB)
Remedy: 1 Check PH cables JLSU1 and J6 for proper connection. Reseat the cables if any abnormality is found. 2 Inspect PH cables and connectors. 3 Replace CTLB. 4 Replace PH.

Code: 4501-111.65

Description: Laser malfunction
Attempted to exceed open loop drive limits.
Causes: • Printhead (PH) • Controller board (CTLB)
Remedy: 1 Check PH cables JLSU1 and J6 for proper connection. Reseat the cables if any abnormality is found. 2 Inspect PH cables and connectors. 3 Replace CTLB. 4 Replace PH.

Code: 4501-111.66

Description: Laser malfunction
Failed alignment of printhead.
Causes: • Printhead (PH) • Controller board (CTLB)
Remedy: 1 Check PH cables JLSU1 and J6 for proper connection. Reseat the cables if any abnormality is found. 2 Inspect PH cables and connectors. 3 Replace CTLB. 4 Replace PH.

Code: 4501-111.67

Description: Laser malfunction
Failed alignment of printhead.
Causes: • Printhead (PH) • Controller board (CTLB)
Remedy: 1 Check PH cables JLSU1 and J6 for proper connection. Reseat the cables if any abnormality is found. 2 Inspect PH cables and connectors. 3 Replace CTLB. 4 Replace PH.

Code: 4501-111.68

Description: Laser malfunction
Too many fake HSYNCs while aligning printhead.
Causes: • Printhead (PH) • Controller board (CTLB)
Remedy: 1 Check PH cables JLSU1 and J6 for proper connection. Reseat the cables if any abnormality is found. 2 Inspect PH cables and connectors. 3 Replace CTLB. 4 Replace PH.

Code: 4501-111.69

Description: Laser malfunction
Too many fake HSYNCs while aligning printhead.
Causes: • Printhead (PH) • Controller board (CTLB)
Remedy: 1 Check PH cables JLSU1 and J6 for proper connection. Reseat the cables if any abnormality is found. 2 Inspect PH cables and connectors. 3 Replace CTLB. 4 Replace PH.

Code: 4901

Description: FW/OS integrity verification error
• NG results from verification of the hash value of the controller FW. • Faulty, damaged, or illegally written ROM data.
Causes: Controller board (CTLB)
Remedy: 1 Turn OFF/ON the main power switch. 2 Rewrite the firmware. 3 Check CTLB for proper connection and correct as necessary. 4 Replace CTLB