Description: Toner density abnormality.
- When the L detection output is in excess of 2.6 V before the toner remaining sensor (PZS) detects a no toner condition, toner density does not recover even when toner is automatically supplied.
Causes: IDC sensor (IDCS) Printer control board (PRCB)
Description: Fusing motor (M11) speed abnormality.
- When M11 is ON, an EM error signal is detected 30 times in succession within a specified period of time.
Causes: Fusing motor (M11) Printer control board (PRCB)
Description: Fusing cooling fan /Fr (FM2) abnormality.
- When FM2 is ON, an EM error signal is detected 3 times in succession within a specified period of time.
Causes: Fusing cooling fan /Fr (FM2) Printer control board (PRCB)
Description: Fusing cooling fan /Rr (FM8) abnormality.
- When FM8 is ON, an EM error signal is detected 3 times in succession within a specified period of time.
Causes: Fusing cooling fan /Rr (FM8) Printer control board (PRCB)
Description: Fusing main sensor high temperature abnormality.
- The thermistor /1 (TH1) detects a temperature higher than 236 °C for more than a specified period of time.
Causes: Thermistor /1 (TH1) Printer control board (PRCB) DC power supply (DCPS)
Description: Fusing sub sensor high temperature abnormality.
- The thermistor /2 (TH2) detects a temperature higher than 236 °C for more than a specified period of time.
Causes: Thermistor /2 (TH2) Printer control board (PRCB) DC power supply (DCPS)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.