Các lỗi thường gặp

Code :
  • Code: C-3801
  • Description: Fusing main sensor low temperature abnormality.
    - While in the idle or in the low power mode, the fusing heater lamp /1 (L2) turns on for more than 12 seconds in succession.
  • Causes: Thermistor /1 (TH1) Printer control board (PRCB) DC power supply (DCPS)
  • Code: C-3802
  • Description: Fusing main sensor low temperature abnormality.
    - While in other than the warm-up, the thermistor /1 (TH1) detects a temperature lower than 130 °C for more than 10 seconds.
  • Causes: Thermistor /1 (TH1) Printer control board (PRCB) DC power supply (DCPS)
  • Code: C-3803
  • Description: Fusing main sensor low temperature abnormality.
    - The detection temperature of the thermistor /1 (TH1) does not get to the prescribed temperature within a specified period of time after it starts the warm-up.
  • Causes: Thermistor /1 (TH1) Printer control board (PRCB) DC power supply (DCPS)
  • Code: C-3804
  • Description: Fusing sub sensor low temperature abnormality.
    - While in the idle, the fusing heater lamp /2 (L3) turns on for more than 12 seconds in succession.
  • Causes: Thermistor /2 (TH2) Printer control board (PRCB) DC power supply (DCPS)
  • Code: C-3805
  • Description: Fusing sub sensor low temperature abnormality.
    - While in other than the warm-up, the thermistor /2 (TH2) detects a temperature lower than 130 °C for more than 10 seconds.
  • Causes: Thermistor /2 (TH2) Printer control board (PRCB) DC power supply (DCPS)
  • Code: C-3806
  • Description: Fusing sub sensor low temperature abnormality.
    - The detection temperature of the thermistor /2 (TH2) does not get to the prescribed temperature within a specified period of time after it starts the warm-up.
  • Causes: Thermistor /2 (TH2) Printer control board (PRCB) DC power supply (DCPS)
  • Code: C-3807
  • Description: Fusing main sensor high temperature abnormality (sub CPU detection)
    - In the sub CPU, the thermistor /1 (TH1) detects a temperature higher than 236 °C for more than a specified period of time.
  • Causes: Thermistor /1 (TH1) Printer control board (PRCB) DC power supply (DCPS)
  • Code: C-3808
  • Description: Fusing sub sensor high temperature abnormality (sub CPU detection)
    - In the sub CPU, the thermistor /2 (TH2) detects a temperature higher than 236 °C for more than a specified period of time.
  • Causes: Thermistor /2 (TH2) Printer control board (PRCB) DC power supply (DCPS)
‹ First  < 5 6 7 8 9 10 11 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục