Code :
- Code: C-6709
- Description: The adjustment data evacuated by resolutions is not available.
- Causes: Overall control board (OACB)
- Code: C-6710
- Description: A density conversion gamma curve cannot be created normally.
- Causes: Overall control board (OACB)
- Code: C-6713
- Description: Despite of the MPC not being terminated, the initial sampling of the APC is attempted.
- Causes: Overall control board (OACB) Image controller firmware
- Code: C-6714
- Description: While executing the APC, the execution of the MPC is attempted.
- Causes: Overall control board (OACB) Image controller firmware
- Code: C-6717
- Description: Sequentially shot page area abnormality. Due to an image area abnormality on the memory, images cannot be developed on the memory.
- Causes: Overall control board (OACB) Image controller firmware
- Code: C-6719
- Description: The scan operation starts before the original skew adjustment is terminated. (The skew adjustment is too late.)
- Causes: Printer control board (PRCB) Original conveyance sensor (PS306) Original skew sensor (PS307)
- Code: C-6720
- Description: The print operation starts before the paper mis-centering adjustment is terminated. (The mis-centering adjustment is too late.)
- Causes: Centering sensor (PS66)
- Code: C-6721
- Description: The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs.
- Causes: Exposure lamp (L1)