Description: Firmware update error A firmware updating sequence is not normally terminated.
Causes: MFP board (MFPB)
Remedy: 1 Check the cable used for updating the firmware for proper connection and correct any faulty connection as necessary. 2 Check the firmware updating file; if the file is not correct, update the firmware again. 3 Check the firmware updating procedure; if the procedure is not correct, update the firmware again. 4 Update the firmware again. 5 Check the MFPB connector for proper connection and correct any faulty connection as necessary. 6 Replace MFPB.
Description: Hard disk access error (connection failure) Unable to communicate between the hard disk and MFP board (MFPB).
Causes: • MFP board (MFPB) • HDD (HDD)
Remedy: 1 Check the connector between hard disk-MFPB CN5, CN13 for proper connection and correct as necessary. 2 Reinstall the hard disk. 3 Replace the hard disk. 4 Replace MFPB.
Description: Hard disk full error The area made available as a user area is full during access to the hard disk.
Causes: • MFP board (MFPB) • HDD (HDD)
Remedy: 1 Set [Admin Settings] -> [Printer Settings] -> [HOLD JOB TIMEOUT] to [Disable]. 2 Check the connector between hard disk-MFPB CN5, CN13 for proper connection and correct as necessary. 3 Format the hard disk. 4 Replace the hard disk. 5 Replace MFPB.