Description: Imaging unit/Y new article release The status with the new unit is not cleared after the new imaging unit is set.
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Code: 2414
Description: Imaging unit/K new article release The status with the new unit is not cleared after the new imaging unit is set.
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Code: 2551
Description: Abnormally low toner density detected cyan TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Remedy: 1 Perform image troubleshooting procedure if image density is low. - - 2 Reinstall the imaging unit - - 3 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 4 M5, M6 operation check PRCB CN22-1 to 4 (M5) PRCB CN22-5 to 8 (M6) 7-I 7-K 5 Replace the imaging unit - - 6 PRCB F5 conduction check - - 7 Replace PRCB
Code: 2552
Description: Abnormally high toner density detected cyan TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Code: 2553
Description: Abnormally low toner density detected magenta TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Remedy: 1 Perform image troubleshooting procedure if image density is low. - - 2 Reinstall the imaging unit - - 3 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 4 M5, M6 operation check PRCB CN22-1 to 4 (M5) PRCB CN22-5 to 8 (M6) 7-I 7-K 5 Replace the imaging unit - - 6 PRCB F5 conduction check - - 7 Replace PRCB
Code: 2554
Description: Abnormally high toner density detected magenta TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Code: 2555
Description: Abnormally low toner density detected yellow TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Remedy: 1 Perform image troubleshooting procedure if image density is low. - - 2 Reinstall the imaging unit - - 3 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 4 M5, M6 operation check PRCB CN22-1 to 4 (M5) PRCB CN22-5 to 8 (M6) 7-I 7-K 5 Replace the imaging unit - - 6 PRCB F5 conduction check - - 7 Replace PRCB
Code: 2556
Description: Abnormally high toner density detected yellow TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB