Description: Imaging unit/Y new article release The status with the new unit is not cleared after the new imaging unit is set.
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Description: Imaging unit/K new article release The status with the new unit is not cleared after the new imaging unit is set.
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Description: Abnormally low toner density detected cyan TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Description: Abnormally high toner density detected cyan TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Description: Abnormally low toner density detected magenta TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Description: Abnormally high toner density detected magenta TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Description: Abnormally low toner density detected yellow TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Description: Abnormally high toner density detected yellow TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively
Causes: • Imaging unit/C,M,Y,K • Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the connector between imaging unit-PRCB CN18, CN19 for proper connection and correct as necessary. - - 3 Replace the imaging unit - - 4 Replace PRCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.