Description: AC signal abnormality The zero cross signal is not input during fusing phase control.
Causes: • Fusing unit • DC power supply (DCPS) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the fusing unit-PRCB CN15, DCPS CN2 for proper connection and correct or change as necessary - - 3 Replace fusing unit - - 4 Replace PRCB - - 5 Replace DCPS
Description: Power supply malfunction A condition is detected in which no power is being supplied to the printer control board (PRCB).
Causes: • PH unit • Toner supply motor/YM (M5) • Toner supply motor/CK (M6) • Front door switch (SW2) • Right door switch (SW3) • DC power supply (DCPS) • Printer control board (PRCB)
Remedy: 1 Check the connector between SW2, SW3-DCPS CN10 for proper connection and correct as necessary. - - 2 Check the connector between M5, M6-PRCB CN22 for proper connection and correct as necessary. - - 3 Check the connector between PH unit-relay CN73- PRCB CN5 for proper connection and correct as necessary. - - 4 M5, M6 operation check PRCB CN22-1 to 4 (M5) PRCB CN22-5 to 8 (M6) 7-I 7-K 5 SW2, SW3 operation check DCPS CN10-1 to 3 1-F 6 Replace the PH unit - - 7 Replace DCPS - - 8 PRCB F5, F10 conduction check - - 9 Replace PRCB
Description: CCD clamp/gain adjustment failure During the CCD gain adjustment, a condition in which the peak value of the output data is equal to, or less than, 64 occurs three consecutive times during retries.
Causes: • Scanner unit • MFP board (MFPB)
Remedy: 1 Check the connector between scanner unit-MFPB CN102, CN103 for proper connection and correct as necessary. - - 2 Check for possible extraneous light and correct as necessary. - - 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. - - 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. - - 5 Replace scanner unit - - 6 Replace MFPB
Description: AFE offset adjustment error During the offset adjustment, the offset value does not fall within the predetermined range a total of three times including retries.
Causes: • Scanner unit • MFP board (MFPB)
Remedy: 1 Check the connector between scanner unit-MFPB CN102, CN103 for proper connection and correct as necessary. - - 2 Check for possible extraneous light and correct as necessary. - - 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. - - 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. - - 5 Replace scanner unit - - 6 Replace MFPB
Description: AFE register setting error There is a mismatch between the set default values of the AFE gain/offset and the gain/offset values read thereafter.
Causes: • Scanner unit • MFP board (MFPB)
Remedy: 1 Check the connector between scanner unit-MFPB CN102, CN103 for proper connection and correct as necessary. - - 2 Check for possible extraneous light and correct as necessary. - - 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. - - 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. - - 5 Replace scanner unit - - 6 Replace MFPB
Description: White reference plate search error The black/white edge on the shading plate cannot be detected during initialization.
Causes: • Scanner unit • MFP board (MFPB)
Remedy: 1 Check the connector between scanner unit-MFPB CN102, CN103 for proper connection and correct as necessary. - - 2 Check for possible extraneous light and correct as necessary. - - 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. - - 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. - - 5 Replace scanner unit - - 6 Replace MFPB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.