Description: CCD clamp/gain adjustment failure
• The adjustment value is 0 or 255 during a CCD clamp adjustment. • The peak value of the output data is 64 or less during a CCD gain adjustment.
Remedy: 1 Correct the harness connection between PWB-A and PWB-C if faulty. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty 4 Correct reflective mirror of the Scanner if faulty, or change Scanner. 5 Change PWB-A. 6 Change PWB-C.
Description: NVRAM initialization failure
• Total Clear is executed in a mode other than the card line mode. • An initial command is issued from the terminal in a mode other than the card line mode. • A new NVRAM is detected in a mode other than the card line mode.
Remedy: 1 Check the PWB-MFP connector for proper connection and correct as necessary. 2 Change PWB-MFP.
Description: Vendor connection failure
• It is detected that communications with the vendor are interrupted for a given period of time or more with "Installed" selected for the setting of vendor installation.
Remedy: 1 Check the Vendor connector for proper connection and correct as necessary. 2 Check the PWB-MC connector for proper connection and correct as necessary. 3 Change PWB-MC.