Description: Abnormally low toner density detected Cyan ATDC Sensor
• T/C 0.21 % or less is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 3 Correct the ATDC Sensor spring moving part if faulty. 4 Clean the ATDC Sensor LED if dirty. 5 Change ATDC Sensor C/M/Y. 6 M3, M4 operation check M3: PWB-MC PJ16MC-4A~7A (Pulse Output) M4: PWB-MC PJ16MC- 10A~13A (Pulse Output) M3: 19-I M4: 19-J. 7 Change Imaging Unit. 8 Change PWB-MC. 9 Change PWB-MFP.
Description: Abnormally high toner density detected Cyan ATDC Sensor
• T/C 15.5 % or more is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 2 Clean the ATDC Sensor LED if dirty. 3 Correct the contact and/or WIRING of the ATDC Sensor if faulty. 4 Change ATDC Sensor C/M/Y. 5 Change Imaging Unit. 6 Change PWB-MC. 7 Change PWB-MFP.
Description: Abnormally low toner density detected Magenta ATDC Sensor
• T/C 0.21 % or less is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 3 Correct the ATDC Sensor spring moving part if faulty. 4 Clean the ATDC Sensor LED if dirty. 5 Change ATDC Sensor C/M/Y. 6 M3, M4 operation check M3: PWB-MC PJ16MC-4A~7A (Pulse Output) M4: PWB-MC PJ16MC- 10A~13A (Pulse Output) M3: 19-I M4: 19-J. 7 Change Imaging Unit. 8 Change PWB-MC. 9 Change PWB-MFP.
Description: Abnormally high toner density detected Magenta ATDC Sensor
• T/C 15.5 % or more is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 2 Clean the ATDC Sensor LED if dirty. 3 Correct the contact and/or WIRING of the ATDC Sensor if faulty. 4 Change ATDC Sensor C/M/Y. 5 Change Imaging Unit. 6 Change PWB-MC. 7 Change PWB-MFP.
Description: Abnormally low toner density detected Yellow ATDC Sensor
• T/C 0.21 % or less is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 3 Correct the ATDC Sensor spring moving part if faulty. 4 Clean the ATDC Sensor LED if dirty. 5 Change ATDC Sensor C/M/Y. 6 M3, M4 operation check M3: PWB-MC PJ16MC-4A~7A (Pulse Output) M4: PWB-MC PJ16MC- 10A~13A (Pulse Output) M3: 19-I M4: 19-J. 7 Change Imaging Unit. 8 Change PWB-MC. 9 Change PWB-MFP.
Description: Abnormally high toner density detected Yellow ATDC Sensor
• T/C 15.5 % or more is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 2 Clean the ATDC Sensor LED if dirty. 3 Correct the contact and/or WIRING of the ATDC Sensor if faulty. 4 Change ATDC Sensor C/M/Y. 5 Change Imaging Unit. 6 Change PWB-MC. 7 Change PWB-MFP.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.