Description: Abnormally low toner density detected Black ATDC Sensor
• T/C 3 % or less is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 M3 operation check PWB-MC PJ16MC-4A~7A (Pulse Output) 19-I. 3 Change Imaging Unit. 4 Change PWB-MC. 5 Change PWB-MFP.
Description: Abnormally high toner density detected Black ATDC Sensor
• T/C 12 % or more is detected ten consecutive times in the Developing Unit as validated through the toner replenishing amount determination control.
Remedy: 1 Correct the ATDC connection on the underside of the Imaging Unit if faulty. 2 Clean or correct each contact of the Imaging Unit if faulty. 3 Change Imaging Unit. 4 Change PWB-MC. 5 Change PWB-MFP.
Description: Cyan ATDC Sensor adjustment failure
• ATDC Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 2 Clean the ATDC Sensor LED if dirty. 3 Correct the contact and/or WIRING of the ATDC Sensor if faulty. 4 Reinstall Imaging Unit C/M/Y. 5 M3, M4 operation check M3: PWB-MC PJ16MC-4A~7A (Pulse Output) M4: PWB-MC PJ16MC-10A~13A (Pulse Output) M3: 19-I M4: 19-J. 6 Change Imaging Unit. 7 Change PWB-MC. 8 Change PWB-MFP.
Remedy: 1 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 2 Clean the ATDC Sensor LED if dirty. 3 Correct the contact and/or WIRING of the ATDC Sensor if faulty. 4 Reinstall Imaging Unit C/M/Y. 5 M3, M4 operation check M3: PWB-MC PJ16MC-4A~7A (Pulse Output) M4: PWB-MC PJ16MC-10A~13A (Pulse Output) M3: 19-I M4: 19-J. 6 Change Imaging Unit. 7 Change PWB-MC. 8 Change PWB-MFP.
Remedy: 1 Clean the ATDC Sensor window on the underside of the Imaging Unit if dirty 2 Clean the ATDC Sensor LED if dirty. 3 Correct the contact and/or WIRING of the ATDC Sensor if faulty. 4 Reinstall Imaging Unit C/M/Y. 5 M3, M4 operation check M3: PWB-MC PJ16MC-4A~7A (Pulse Output) M4: PWB-MC PJ16MC-10A~13A (Pulse Output) M3: 19-I M4: 19-J. 6 Change Imaging Unit. 7 Change PWB-MC. 8 Change PWB-MFP.
Remedy: 1 Correct the ATDC connection on the underside of the Imaging Unit if faulty. 2 Clean or correct each contact of the Imaging Unit if faulty. 3 Change Imaging Unit. 4 Change PWB-MC. 5 Change PWB-MFP.
Description: Standard controller configuration failure
• The controller of the MFP Control Board (PWB-MFP) is faulty.
Remedy: 1 Check to see if the following setting has been correctly made: Tech. Rep. Mode - ?gSystem Input - Peripheral Setting. If the setting is changed, be sure to turn OFF and ON the Power Switch. 2 Check the connectors of the MFP Control Board (PWB-MFP) for proper connection and correct as necessary. 3 Change PWB-MFP.
Description: File Memory mounting error
• The File Memory mounted on the MFP Control Board (PWB-MFP) is faulty.
Remedy: 1 Check to see if the standard memory (DIMMS0) on the MFP Control Board (PWB-MFP) is installed correctly. 2 Change the standard memory (DIMMS0) on the MFP Control Board (PWB-MFP). 3 Change PWB-MFP.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.