Các lỗi thường gặp

Code :
  • Code: C3426
  • Description: Fusing temperature increase malfunction (TEM1: edge) • Detected temperature of the fusing temperature sensor/1 (TEM1: center and edge) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
  • Causes: • Fusing unit • C3421: Fusing temperature sensor/1 (TEM1: center) • C3426: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.
  • Code: C3722
  • Description: Fusing abnormally high temperature (TEM2) Detected temperature of the fusing temperature sensor/2 (TEM2) goes beyond a given temperature for a given period of time consecutively.
  • Causes: • Fusing unit • C3722: Fusing temperature sensor/2 (TEM2) • C3725: Fusing temperature sensor/1 (TEM1: center) • C3726: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
  • Code: C3725
  • Description: Fusing abnormally high temperature (TEM1: center) Detected temperature of the fusing temperature sensor/1 (TEM1: center) goes beyond a given temperature for a given period of time consecutively.
  • Causes: • Fusing unit • C3722: Fusing temperature sensor/2 (TEM2) • C3725: Fusing temperature sensor/1 (TEM1: center) • C3726: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
  • Code: C3726
  • Description: Fusing abnormally high temperature (TEM1: edge) Detected temperature of the fusing temperature sensor/1 (TEM1: edge) goes beyond a given temperature for a given period of time consecutively.
  • Causes: • Fusing unit • C3722: Fusing temperature sensor/2 (TEM2) • C3725: Fusing temperature sensor/1 (TEM1: center) • C3726: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
  • Code: C3731
  • Description: Fusing abnormally high temperature (Hard protector) An abnormally high temperature of the hard protector signal is detected.
  • Causes: • Fusing unit • Fusing temperature sensor/1 (TEM1: center) • Fusing temperature sensor/2 (TEM2) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
  • Code: C3822
  • Description: Fusing abnormally low temperature (TEM2) The fusing temperature sensor/2 (TEM2) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
  • Causes: • Fusing unit • C3822: Fusing temperature sensor/2 (TEM2) • C3825: Fusing temperature sensor/1 (TEM1: center) • C3826: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.
  • Code: C3825
  • Description: Fusing abnormally low temperature (TEM1: center) The fusing temperature sensor/1 (TEM1: center) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
  • Causes: • Fusing unit • C3822: Fusing temperature sensor/2 (TEM2) • C3825: Fusing temperature sensor/1 (TEM1: center) • C3826: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.
  • Code: C3826
  • Description: Fusing abnormally low temperature (TEM1: edge) The fusing temperature sensor/1 (TEM1: edge) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
  • Causes: • Fusing unit • C3822: Fusing temperature sensor/2 (TEM2) • C3825: Fusing temperature sensor/1 (TEM1: center) • C3826: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
  • Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.