Description: • C5102: Main motor failure to turn • C5103: Main motor turning at abnormal timing Trouble detection condition • C5102: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • C5103: The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Main motor (M1) • MFP board (MFPB)
Remedy: 1. Check the connector between M1-MFPB CN6E for proper connection and correct as necessary. 2. M1 operation check • Control signal: MFPB CN6E-4 to 7 • Location of electrical component: 2-C 3. Replace M1. 4. MFPB F9E conduction check 5. Replace MFPB.
Description: UFP fan motor failure The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • UFP fan motor (FM5) • MFP board (MFPB)
Remedy: 1. Check the connector between FM5-relay CN158-relay CN90-MFPB CN10E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM5 operation check • Control signal: MFPB CN10E-9 (LOCK) • Location of electrical component: 5-C 4. Replace FM5. 5. MFPB F2E and F4E conduction check 6. Replace MFPB.
Description: DC power supply fan motor failure. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • DC power supply fan motor (FM1) • MFP board (MFPB)
Remedy: 1. Check the connector between FM1-relay CN304-MFPB CN12E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM1 operation check • Control signal: MFPB CN12E-15 (LOCK) • Location of electrical component: 27-C 4. Replace FM1. 5. MFPB F2E conduction check 6. Replace MFPB.
Description: Cooling fan motor/2 failure (Europe model only) The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Cooling fan motor/2 (FM6) • MFP board (MFPB)
Remedy: 1. Check the connector between FM6-relay CN302-MFPB CN12E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM6 operation check • Control signal: MFPB CN12E-12 (LOCK) • Location of electrical component: 27-C 4. Replace FM6. 5. MFPB F2E conduction check 6. Replace MFPB.
Description: Cooling fan motor/1 failure The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Cooling fan motor/1 (FM2) • MFP board (MFPB)
Remedy: 1. Check the connector between FM2-relay CN303-MFPB CN12E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM2 operation check • Control signal: MFPB CN12E-9 (LOCK) • Location of electrical component: 26-C 4. Replace FM2. 5. MFPB F2E conduction check 6. Replace MFPB.
Description: Clean unit fan's failure to turn (When CU-202 is installed) The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Remedy: 1. Check the connector between CUDB CN1-relay CN400-MFPB CN26E for proper connection and correct as necessary. 2. Check the connector between FM1-relay CN401-CUDB CN2 for proper connection and correct as necessary. 3. Check the connector between FM2-relay CN402-CUDB CN2 for proper connection and correct as necessary. 4. Check the connector between FM3-relay CN403-CUDB CN2 for proper connection and correct as necessary. 5. Check the fan for possible overload and correct as necessary. 6. FM1 operation check • Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK) • Location of electrical component: 26-L 7. FM2 operation check • Control signal: CUDB CN2-4 (REM), CUDB CN2-6 (LOCK) • Location of electrical component: 27-L 8. FM3 operation check • Control signal: CUDB CN2-7 (REM), CUDB CN2-9 (LOCK) • Location of electrical component: 27-L 9. Replace the defective fan. (FM1 / FM2 / FM3) 10. Replace CUDB. 11. MFPB F11E conduction check 12. Replace MFPB.
Description: MFP control board CPU temperature failure Temperature failure of CPU on the MFP board was detected.
Causes: MFP board (MFPB)
Remedy: 1. Reboot the machine. 2. Check for clogging in the ventilation path between the MFPB and the power supply cooling fan, and correct as necessary. 3. Replace MFPB.
Description: AC signal abnormality. The zero cross signal is not input during fusing phase control.
Causes: • Fusing unit • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check DCPS CN3-MFPB CN1E for proper connection and correct or change as necessary. 3. Check the fusing unit-DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.