Description: Fusing temperature increase malfunction (TEM1: edge) • Detected temperature of the fusing temperature sensor/1 (TEM1: center and edge) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The warm-up is not completed even after the set period of time has elapsed after the warm-up is started.
Causes: • Fusing unit • C3421: Fusing temperature sensor/1 (TEM1: center) • C3426: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.
Description: Fusing abnormally high temperature (TEM2) Detected temperature of the fusing temperature sensor/2 (TEM2) goes beyond a given temperature for a given period of time consecutively.
Causes: • Fusing unit • C3722: Fusing temperature sensor/2 (TEM2) • C3725: Fusing temperature sensor/1 (TEM1: center) • C3726: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
Description: Fusing abnormally high temperature (TEM1: center) Detected temperature of the fusing temperature sensor/1 (TEM1: center) goes beyond a given temperature for a given period of time consecutively.
Causes: • Fusing unit • C3722: Fusing temperature sensor/2 (TEM2) • C3725: Fusing temperature sensor/1 (TEM1: center) • C3726: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
Description: Fusing abnormally high temperature (TEM1: edge) Detected temperature of the fusing temperature sensor/1 (TEM1: edge) goes beyond a given temperature for a given period of time consecutively.
Causes: • Fusing unit • C3722: Fusing temperature sensor/2 (TEM2) • C3725: Fusing temperature sensor/1 (TEM1: center) • C3726: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
Description: Fusing abnormally high temperature (Hard protector) An abnormally high temperature of the hard protector signal is detected.
Causes: • Fusing unit • Fusing temperature sensor/1 (TEM1: center) • Fusing temperature sensor/2 (TEM2) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. Replace DCPS.
Description: Fusing abnormally low temperature (TEM2) The fusing temperature sensor/2 (TEM2) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
Causes: • Fusing unit • C3822: Fusing temperature sensor/2 (TEM2) • C3825: Fusing temperature sensor/1 (TEM1: center) • C3826: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.
Description: Fusing abnormally low temperature (TEM1: center) The fusing temperature sensor/1 (TEM1: center) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
Causes: • Fusing unit • C3822: Fusing temperature sensor/2 (TEM2) • C3825: Fusing temperature sensor/1 (TEM1: center) • C3826: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.
Description: Fusing abnormally low temperature (TEM1: edge) The fusing temperature sensor/1 (TEM1: edge) continues to detect a temperature lower than a predetermined one for a predetermined period of time after warm-up is complete.
Causes: • Fusing unit • C3822: Fusing temperature sensor/2 (TEM2) • C3825: Fusing temperature sensor/1 (TEM1: center) • C3826: Fusing temperature sensor/1 (TEM1: edge) • DC power supply (DCPS) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the upper right door. 3. Check the fusing unit-MFPB CN13E, DCPS CN2 for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB. 6. DCPS F102 conduction check 7. Replace DCPS.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.