Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub C652DS — Trang 9/28

Code: C2152

Description: Transfer belt pressure welding alienation
• At the completion of transfer belt pressure/ retraction operations, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. •Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. Operation Position Sensor status (K: Color) • Color and K retraction - K pressure • Color and K pressure - K K pressure ON (not blocked) :OFF (blocked) pressure • Color and K retraction - Color and K pressure • K pressure - Color and K pressure Color and K pressure ON (not blocked):ON (not blocked) • K pressure - Color and K retraction • Color and K pressure - Color and K Color and K retraction OFF (blocked): OFF (blocked) retraction
Causes: Pressure welding alienation sensor/K (PS51) Pressure welding alienation sensor/color (PS52) 1st image transfer pressure retraction motor (M21) Printer control board (PRCB)
Remedy: 1 Check the M21 connector for proper connection and correct as necessary. - - 2 PS51 I/O check, sensor check PRCB CN21-1 (ON) C-23 3 PS52 I/O check, sensor check PRCB CN21-4 (ON) C-23 4 M21 operation check PRCB CN20-1 to 4 K-6 5 Change M21 - - 6 PRCB ICP4 conduction check - - 7 Change MFPB

Code: C2160

Description: PC charge (C) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB

Code: C2161

Description: PC charge (M) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB

Code: C2162

Description: PC charge (Y) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB

Code: C2163

Description: PC charge (K) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB

Code: C2164

Description: PC charge malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB

Code: C2204

Description: Waste toner agitating motor’s failure to turn
•The waste toner agitating motor lock sensor continues to be blocked or unblocked for a predetermined period of time when the motor is turning.
Causes: Waste toner agitating motor lock sensor (PS23) Waste toner agitating motor (M20) Printer control board (PRCB)
Remedy: 1 Clean the PS23 if it has toner or paper dust, etc. - - 2 Change the waste toner box. - - 3 Check the M20 connector for proper connection and correct as necessary. - - 4 Check the connector of motor for proper drive coupling and correct as necessary. - - 5 M20 operation check PRCB CN23-1 to 4 C-8 to 9 6 Change M20 - - 7 PRCB ICP3 conduction check - - 8 Change PRCB

Code: C2253

Description: Color PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: Color PC drum motor (M16) Printer control board (PRCB)
Remedy: 1 Check the M16 connector for proper connection and correct as necessary. - - 2 Check the M16 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M16 operation check PRCB CN34-8 (REM) PRCB CN34-11 (LOCK) K-1 5 Change M16 - - 6 PRCB ICP13 conduction check - - 7 Change PRCB
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie