Description: Fusing abnormally low temperature detection (Edge of the heating roller) The heating roller thermistor/3 continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Causes: • Fusing unit • Heating roller thermistor/3 (TH3) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace IHPU. 6 Replace PRCB. 7 Replace NF1.
Code: C3825
Description: Fusing abnormally low temperature detection (Main of the heating roller) The heating roller temperature sensor continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Causes: • Fusing unit • Heating roller temperature sensor (TEMS2) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace IHPU. 6 Replace PRCB. 7 Replace NF1.
Code: C3903
Description: Thermostat tripping During warm-up, the thermostat tripping detection signal continues to be H for the set period of time.
Causes: • Fusing unit • Heating roller thermostat (TS1) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace IHPU. 6 Replace PRCBn.
Code: C3922
Description: Fusing sensor wire breaks detection (Edge of the heating roller) After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/3 voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Causes: • Fusing unit • Heating roller thermistor/3 (TH3) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace IHPU. 6 Replace PRCB. 7 Replace NF1.
Code: C3925
Description: Fusing sensor wire breaks detection (Main of the heating roller) After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time.
Causes: • Fusing unit • Heating roller temperature sensor (TEMS2) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace IHPU. 6 Replace PRCB. 7 Replace NF1.
Code: C3926
Description: Fusing sensor wire breaks detection (Center of the heating roller) After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/2 voltage does not decrease by predetermined steps (temperature rise) within a predetermined time.
Causes: • Fusing unit • Heating roller thermistor/2 (TH2) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace IHPU. 6 Replace PRCB. 7 Replace NF1.
Code: C392A
Description: Heating roller temperature sensor contamination (Center of the heating roller) While checking the contamination on the heating roller temperature sensor, detected temperature of the heating roller thermistor/1 exceeded the detected temperature of the heating roller temperature sensor for over the predetermined value for the predetermined period of time.
Causes: • Fusing unit • Heating roller temperature sensor (TEMS2) • Heating roller thermistor/1 (TH1) • IH power supply (IHPU) • DC power supply (DCPU) • Printer control board (PRCB)
Remedy: 1 Wipe the TEMS2 clean of dirt if any. <Cleaning procedure> • Clear away a dirt or a foreign object on the sensor with a cotton swab. • When a dirt is left even if you cleaned the sensor by above procedure, clear away a dirt or a foreign object on the sensor using a cotton swab dampened with the alcohol. And, wipe off the sensor with a dry cotton swab afterwards. 2 Check the TEMS2 for installed position and proper connector connection. - - 3 Check the TH1 for installed position and proper connector connection. - - 4 Check the connection of the fusing unit. 5 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary. 6 Replace the fusing unit. 7 Replace PRCB.
Code: C3B02
Description: IH malfunction (CPU) A failure in communication with the fusing CPU continues for a predetermined period of time.
Causes: • Fusing unit • IH coil unit • IH power supply (IHPU) • IH magnetic erasing board (IHMEB) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IH coil unit, IHPU, IHMEB, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace the IH coil unit. 6 Replace IHPU. 7 Replace IHMEB. 8 PRCB ICP5 conduction check. 9 Replace PRCB. 10 Replace NF1.