Description: Finisher ROM error (RU). When a communication error is detected between the main body and the horizontal transport unit.
Causes: • RU control board (RUCB) • FS control board (FSCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. - - 2 Rewrite the firmware. - - 3 Replace RUCB - - 4 Replace FSCB
Code: CC159, CC15A
Description: ROM contents error upon startupA fault is detected in a sequence of ROM contents check of the DSC board during starting. (DSC1), ROM contents error upon startup (DSC2).
Causes: DSC board (SC-508)
Remedy: 1 Check the DSC board connector for proper connection and correct as necessary. - - 2 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. - - 3 Rewrite the firmware. - - 4 Replace DSC board
Code: CC15B
Description: Finisher ROM error (SD). Data of flash ROM of the saddle unit is determined to be faulty when the power is turned ON.
Causes: SD drive board (SDDB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. - - 2 Rewrite the firmware. - - 3 Replace SDDB(SD-511/SD-512)
Code: CC163
Description: ROM contents error (PRT). The wrong model of firmware is detected in the engine during the initial connection to the engine is being checked.
Causes: • SSD board (SSDB) • Printer control board (PRCB)
Remedy: 1 Rewrite the firmware. - - 2 Replace PRCB - - 1. Turn OFF the main power switch and replace the current PRCB with a new one. 2. Update the PRCB firmware. 3. After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started. 4. When the trouble cannot be solved, reinstall the removed PRCB to the original board. NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SSDB. 3 If the above actions do not solve the problem, contact KMBT.
Code: CC164
Description: ROM contents error (MSC). The wrong model of firmware is detected in the MFP board when the main power switch is turned ON.
Causes: • Printer control board (PRCB) • MFP board (MFPB)
Remedy: 1 Check the ROM version. - - 2 Rewrite the firmware. - - 3 Replace the corresponding board. - - 4 When not reviving even if the above-mentioned procedure is done, contact the responsible people of KMBT.
Code: CC165
Description: ROM contents error (DF). When the power is turned ON, DF control board or firmware error is detected.
Causes: DF control board (DFCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. - - 2 Rewrite the firmware. - - 3 Replace DFCB
Code: CC170...CC186
Description: Dynamic link error during starting (AP0) Dynamic link error during starting (AP1) Dynamic link error during starting (AP2) Dynamic link error during starting (AP3) Dynamic link error during starting (AP4) Dynamic link error during starting (LDR) Dynamic link error during starting (IBR) Dynamic link error during starting (IID) Dynamic link error during starting (IPF) Dynamic link error during starting (IMY) Dynamic link error during starting (SPF) Dynamic link error during starting (OAP). A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
Causes: MFP board (MFPB)
Remedy: 1 If the malfunction code "C-C172" has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if "Controller 2," "Controller 3," or "Others" is set for [Image Controller Setting]. If any of these is set, according to the kind of controller, select "Controller 0" or "Controller 1." - - 2 If the malfunction code "C-C180" has occurred, check to install the appropriate loadable driver for an authentication unit which is installed to the MFP. - - 3 Replace MFPB - - 4 When not reviving even if the above-mentioned procedure is done, contact the responsible people of KMBT.
Code: CC190
Description: Outline font load error. An error occurred while loading the outline font.
Causes: • MFP board (MFPB) • Hard disk
Remedy: 1 Check the hard disk connector for proper connection and correct as necessary. - - 2 Format the hard disk. - - 3 Replace the hard disk. - - 4 Replace MFPB