Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Fr (FM1) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /Fr (FM1) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /1, /2 (FM2, FM6) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /1, /2 (FM2, FM6) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Mi (FM3) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /Mi (FM3) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: An error detection signal is detected for a specified period of time in succession while the motor cooling fan motor (FM4) of the tandem (2nd) LS is ON.
Causes: Motor cooling fan motor (FM4) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Rr (FM5) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /Rr (FM5) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The tray up down motor (M3) does not turn OFF even when a specified period of time elapses after it starts operations. Or, it operates for more than the allowed time at a speed out of the specified one.
Causes: FNS control board (FNSCB) FNS drive board (FNSDB) Tray up down motor (M3) Tray upper limit sensor (PS2) Tray lower limit sensor (PS3)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The alignment home sensors /Rr (PS8) and /Fr (PS31) do not turn ON within a specified period of time after the home position search operation of the alignment motors /Rr (M5) and /Fr (M22) starts.
Causes: FNS control board (FNSCB) FNS drive board (FNSDB) Alignment motor /Rr (M5) Alignment motor /Fr (M22) Alignment home sensor /Rr (PS8) Alignment home sensor /Fr (PS31)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.