Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 1050eP — Trang 11/42

Code: SC32-06

Description: The blowout of a fuse for the pump cooling fan (FM11) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM11 EM signal a specified period of time after the FM11 is turned ON. This abnormal condition recurs even a specified period of time after the FM11 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected.
Causes: Pump cooling fan (FM11) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC32-07

Description: The rotation of the pump cooling fan (FM11) is checked. An abnormal condition occurs with the FM11 EM signal a specified period of time after the FM11 is turned ON. This abnormal condition recurs even a specified period of time after the FM11 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: Pump cooling fan (FM11) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC32-09

Description: The rotation of the transfer/separation suction fan (FM4) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after the FM4 is turned ON. This abnormal condition recurs even a specified period of time after the FM4 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /1 (DCPS/ 1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC32-10

Description: The blowout of a fuse for the transfer/separation suction fan (FM4) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after the FM4 is turned ON. This abnormal condition recurs even a specified period of time after the FM4 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
Causes: Transfer/separation suction fan (FM4) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC32-11

Description: The rotation of the transfer/separation suction fan (FM4) is checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after the FM4 is turned ON. This abnormal condition recurs even a specified period of time after the FM4 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of a fuse) is not detected.
Causes: Transfer/separation suction fan (FM4) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC32-12

Description: The rotation of the developing suction fan (FM5) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after the FM5 is turned ON. This abnormal condition recurs even a specified period of time after the FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /1 (DCPS/ 1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC32-13

Description: The blowout of a fuse for the developing suction fan (FM5) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after the FM5 is turned ON. This abnormal condition recurs even a specified period of time after the FM5 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal
Causes: Developing suction fan (FM5) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC32-14

Description: The rotation of the developing suction fan (FM5) is checked. An abnormal condition occurs with the FM5 EM signal a specified period of time after the FM5 is turned ON. This abnormal condition recurs even a specified period of time after the FM5 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of a fuse) is not detected.
Causes: Developing suction fan (FM5) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).