Code :
  • Code: SC32-15
  • Description: The rotation of the paper exit cooling fan /1 (FM9) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after the FM9 is turned ON. This abnormal condition recurs even a specified period of time after the FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
  • Causes: DC power supply /1 (DCPS/ 1)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-16
  • Description: The blowout of a fuse for the paper exit cooling fan /1 (FM9) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after the FM9 is turned ON. This abnormal condition recurs even a specified period of time after the FM9 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
  • Causes: Paper exit cooling fan /1 (FM9) Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-17
  • Description: The rotation of the paper exit cooling fan /1 (FM9) is checked. An abnormal condition occurs with the FM9 EM signal a specified period of time after the FM9 is turned ON. This abnormal condition recurs even a specified period of time after the FM9 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of a fuse) is not detected.
  • Causes: Paper exit cooling fan /1 (FM9) Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-18
  • Description: The rotation of the paper exit cooling fan /2 (FM10) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after the FM10 is turned ON. This abnormal condition recurs even a specified period of time after the FM10 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
  • Causes: DC power supply /1 (DCPS/ 1)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-19
  • Description: The blowout of a fuse for the paper exit cooling fans /2 (FM10) and /3 (FM28) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after the FM10 is turned ON. This abnormal condition recurs even a specified period of time after the FM10 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
  • Causes: Paper exit cooling fans /2 (FM10), /3 (FM28)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-20
  • Description: The rotation of the paper exit cooling fans /2 (FM10) and /3 (FM28) is checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after the FM10 is turned ON. This abnormal condition recurs even a specified period of time after the FM10 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
  • Causes: Paper exit cooling fans /2 (FM10), /3 (FM28)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-21
  • Description: The rotation of the paper feed assist fan /Fr1 (FM20) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM20 EM signal a specified period of time after the FM20 is turned ON. This abnormal condition recurs even a specified period of time after the FM20 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
  • Causes: DC power supply /1 (DCPS/ 1)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC32-22
  • Description: The blowout of a fuse for the paper feed assist fan /Fr1 (FM20) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM20 EM signal a specified period of time after the FM20 is turned ON. This abnormal condition recurs even a specified period of time after the FM20 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
  • Causes: Paper feed assist fan /Fr1 (FM20) Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).