Description: The rotation of the paper feed assist fan /Fr3 (FM45) is checked. An abnormal condition occurs with the FM45 EM signal a specified period of time after the FM45 is turned ON. This abnormal condition recurs even a specified period of time after the FM45 is turned OFF and then turned ON, and no error detection signal (24V cut off/blowout of a fuse) is detected.
Causes: Paper feed assist fan /Fr3 (FM45) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-48
Description: The rotation of the paper feed assist fan /Rr3 (FM46) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after the FM46 is turned ON. This abnormal condition recurs even a specified period of time after the FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-49
Description: The blowout of a fuse for the paper feed assist fan /Rr3 (FM46) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after the FM46 is turned ON. This abnormal condition recurs even a specified period of time after the FM46 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
Causes: Paper feed assist fan /Rr3 (FM46) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-50
Description: The rotation of the paper feed assist fan /Rr3 (FM46) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after the FM46 is turned ON. This abnormal condition recurs even a specified period of time after the FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: Paper feed assist fan /Rr3 (FM46) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-51
Description: The rotation of the cooling fan (FM20) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after the FM46 is turned ON. This abnormal condition recurs even a specified period of time after the FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-52
Description: The blowout of a fuse for the cooling fan (FM20) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after the FM46 is turned ON. This abnormal condition recurs even a specified period of time after the FM46 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
Causes: Cooling fan (FM20) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-53
Description: The rotation of the cooling fan (FM20) is checked. An abnormal condition occurs with the FM46 EM signal a specified period of time after the FM46 is turned ON. This abnormal condition recurs even a specified period of time after the FM46 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: Cooling fan (FM20) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-54
Description: The rotation of the power supply cooling fan /3 (FM27) is checked. An abnormal condition occurs with the FM27 EM signal a specified period of time after the FM27 is turned ON. This abnormal condition recurs even a specified period of time after the FM27 is turned OFF and then turned ON, and no error detection signal (24V cut off/blowout of a fuse) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).