Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC35-01
Description: Thermistor /1 (TH1) low temperature detection (software). The TH1 does not get to 50°C when a specified period of time elapses after the main switch (SW1) is turned ON for the fusing ON control.
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC35-02
Description: Thermistor /3 (TH3) low temperature detection (software). The TH3 does not get to 50°C when a specified period of time elapses after the main switch (SW1) is turned ON for the fusing ON control.
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC36-01
Description: Thermistor /1 (TH1) high temperature detection (long time/software). The TH1 detects a temperature of 200°C or above 30 times in a row in a period of 1 second.
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC36-02
Description: Thermistor /3 (TH3) high temperature detection (long time/software). The TH3 detects a temperature of 220°C or above 30 times in a row in a period of 1 second.
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC36-03
Description: Thermistor /1 (TH1) low temperature detection (hardware). The TH1 detects an abnormal condition with the fusing error detection signal 2.
Causes: Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) Thermistor /3 (TH3) Thermistor /4 (TH4) Caution: • When SC34-**, SC35-** or SC36-** (fusing temperature related abnormalities) occur, be sure to repair defective parts before setting the software DIPSW3-1 to 0. Setting the DIPSW3- 1 to 0 with defective parts not repaired may result in a fire.
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC36-04
Description: Thermistor /3 (TH3) low temperature detection (hardware). The TH3 detects an abnormal condition with the fusing error detection signal 5.
Causes: Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) Thermistor /3 (TH3) Thermistor /4 (TH4) Caution: • When SC34-**, SC35-** or SC36-** (fusing temperature related abnormalities) occur, be sure to repair defective parts before setting the software DIPSW3-1 to 0. Setting the DIPSW3- 1 to 0 with defective parts not repaired may result in a fire.
Remedy: The main body stops immediately to turn OFF the RL1 (main).