Các lỗi thường gặp

Code :
  • Code: SC32-55
  • Description: The EM signal of the power supply cooling fan /3 (FM27) is ON when starting the print.
  • Causes: DC power supply /2 (DCPS/ 2)
  • Remedy: Error codes are not displayed on the operation board, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.
  • Code: SC33-01
  • Description: The blowout of a fuse for the motor of the registration section in the ADU drive board /2 (ADUDB2) is checked. An error detection signal (blowout of a fuse) of the ADU conveyance motor /2 (M16)/ registration motor (M17)/loop motor (M18) is detected after the print is started. At this time, the closing of the door detection/PFU door is detected 10 times in succession.
  • Causes: ADU drive board /2 (ADUDB2) ADU conveyance motor /2 (M16) Registration motor (M17) Loop motor (M18)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC33-02
  • Description: The blowout of a fuse for the ADU motor in the ADU drive board /1 (ADUDB1) is checked. An error detection signal (blowout of a fuse) of the reverse/exit motor (M13)/ADU acceleration motor (M14)/ ADU conveyance motor /1 (M15)/ADU reverse motor (M12) is detected after the print is started. At this time, the closing of the door detection/PFU door is detected 10 times in succession.
  • Causes: ADU drive board /1 (ADUDB1) Reverse/exit motor (M13) ADU accelerate motor (M14) ADU conveyance motor /1 (M15) ADU reverse motor (M12)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC33-04
  • Description: The blowout of a fuse for the transfer assist motor (M19) in the printer control board (PRCB) is checked. When the M19 turns ON from OFF, an error detection signal (blowout of a fuse) is detected. At this time, the closing of the door is detected 10 times in succession.
  • Causes: Printer control board (PRCB) Transfer assist motor (M19)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC33-05
  • Description: The blowout of a fuse for the web motor (M24) in the printer control board (PRCB) is checked, and the 24V power source is also checked. When the M24 turn ON from OFF, error detection signals (blowout of a fuse and the 24V cut off) are detected.
  • Causes: DC power supply /2 (DCPS/ 2)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC33-06
  • Description: The blowout of a fuse for the web motor (M24) in the printer control board (PRCB) is checked. When the M24 turns ON from OFF, an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected.
  • Causes: Printer control board (PRCB) Web motor (M24)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC34-01
  • Description: Thermistor /1 (TH1) high temperature detection (software). The TH1 detects a temperature of 210°C or above 5 times in a period of 1 second.
  • Causes: Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) Thermistor /3 (TH3) Thermistor /4 (TH4)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC34-02
  • Description: Thermistor /3 (TH3) high temperature detection (software). The TH3 detects a temperature of 230°C or above 5 times in a period of 1 second.
  • Causes: Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /2 (TH2) Thermistor /3 (TH3) Thermistor /4 (TH4)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).