Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 1050P — Trang 20/42

Code: SC42-02

Description: The blowout of a fuse for the scanner cooling fan (FM19) in the scanner drive board (SDB) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after the FM19 turns ON. This abnormal condition recurs even a specified period of time after the FM19 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected.
Causes: Scanner drive board (SDB) Scanner cooling fan (FM19)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC42-03

Description: The rotation of the scanner cooling fan (FM19) is checked. An abnormal condition occurs with the FM19 EM signal a specified period of time after the FM19 turns ON. This abnormal condition recurs even a specified period of time after the FM19 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: Scanner cooling fan (FM19)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC42-04

Description: The rotation of the suction fan /1 (FM6) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after the FM6 turns ON. This abnormal condition recurs even a specified period of time after the FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC42-05

Description: The blowout of a fuse for the suction fan /1 (FM6) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after the FM6 turns ON. This abnormal condition recurs even a specified period of time after the FM6 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected.
Causes: AC drive board (ACDB) Suction fan /1 (FM6)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC42-06

Description: The rotation of the suction fan /1 (FM6) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after the FM6 turns ON. This abnormal condition recurs even a specified period of time after the FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: AC drive board (ACDB) Suction fan /1 (FM6)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC42-07

Description: The EM signal of the suction fan /1 (FM6) is ON when the printing is started.
Causes: Suction fan /1 (FM6)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC42-08

Description: The rotation of the suction fans /2 (FM7) and /3 (FM8) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM7/FM8 EM signal a specified period of time after the FM7/FM8 turns ON. This abnormal condition recurs even a specified period of time after the FM7/FM8 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC42-09

Description: The blowout of a fuse for the suction fans /2 (FM7) and /3 (FM8) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM7/FM8 EM signal a specified period of time after the FM7/FM8 turns ON. This abnormal condition recurs even a specified period of time after the FM7/FM8 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time an error detection signal (24V cut off) is not detected.
Causes: AC drive board (ACDB) Suction fan /2 (FM7) Suction fan /3 (FM8)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie