Description: Thermistor /1 (TH1) low temperature abnormality 1 (hardware). TH1 detects the fusing abnormality detection signal 3.
Causes: Fusing temperature sensor /1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 6
Causes: Fusing temperature sensor /3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Image processing cooling fan (FM12) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM12 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Image processing cooling fan (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected
Causes: Image processing cooling fan (FM12) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 3 Replace FM12 and ACDB at a time.
Description: Image processing cooling fan (FM12) rotation abnormality 1. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Image processing cooling fan (FM12) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM12. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Image processing cooling fan (FM12) rotation abnormality 2. When the print is started, the EM signal of FM12 turns ON.
Causes: Image processing cooling fan (FM12) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM12. - 5 Replace PRCB. - 6 Replace ACDB.
Description: LPH fan (FM3) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM3 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: LPH fan (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: LPH fan /1 (FM3) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 3 Replace FM3 and ACDB at a time.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.