Description: DC power supply /3 cooling fan (FM36) power abnormality. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: DC power supply /3 cooling fan (FM36) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM36 and ACDB at a time.
Description: DC power supply /3 cooling fan (FM36) rotation abnormality 1. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: DC power supply /3 cooling fan (FM36) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM36. - 4 Replace PRCB.
Description: DC power supply /3 cooling fan (FM36) rotation abnormality 2. When the print is started, the EM signal of FM36 turns ON.
Causes: DC power supply /3 cooling fan (FM36) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM36. - 4 Replace PRCB.
Description: Scanner motor (M27) movement time abnormality + 24V power abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (24V cut off) of M27 is detected.
Causes: DC power supply /1 (DCPS/1) Scanner drive board (SDB)
Remedy: Check the connector connection and the wiring between SDB and DCPS /1, and repair it if any abnormality. - 2 Replace DCPS /1. - 3 Replace SDB.
Description: Scanner motor (M27) power abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected.
Causes: Scanner motor (M27) Scanner drive board (SDB)
Remedy: 1 Check the connector connection and the wiring between SDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 1-F 3 Replace M27 and SDB at a time.
Description: Scanner motor (M27) movement time abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (blowout of a fuse/24V cut off) of M27 is not detected.
Causes: Scanner home sensor (PS51) APS sensor /1 (PS52) Scanner motor (M27) Scanner drive board (SDB)
Remedy: 1 Check the scanner drive section, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 2-F 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 1-F 5 Replace PS51 and PS52. - 6 Replace M27. - 7 Replace SDB.
Description: Scanner cooling fan (FM19) rotation abnormality + 24V power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) Scanner drive board (SDB)
Remedy: 1 Check the connector connection and the wiring between SDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace SDB.
Description: Scanner cooling fan (FM19) power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected.
Causes: Scanner cooling fan (FM19) Scanner drive board (SDB)
Remedy: 1 Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-F 3 Replace FM19 and SDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.