Description: Cooling fan /1 (FM1) rotation abnormality. When the print is started, the EM signal of FM1 turns ON.
Causes: Cooling fan /1 (FM1) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 4 Replace FM1. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Cooling fan /2 (FM2) rotation abnormality 2. When the print is started, the EM signal of FM2 turns ON.
Causes: Cooling fan /2 (FM2) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 4 Replace FM2. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Suction cooling fan /1 (FM6) rotation abnormality 2. When the print is started, the EM signal of FM6 turns ON.
Causes: Suction cooling fan /1 (FM6) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM6. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Abnormality of the fun connected to ADU drive board. The EM error detection signal is detected twice in succession within a specified period of time after ADU cooling fan /1 (FM14), /2 (FM15), /3 (FM13), sensor cooling fan /1 (FM16) and registration cooling fan (FM17) connected to ADU drive board was turned ON. At this time, the door close detection of the door open/close sensor /1 (PS1), /2 (PS2) and PF door open/close sensor (PS70) is detected 10 times in succession.
Causes: ADU cooling fan /1 (FM14) ADU cooling fan /2 (FM15) ADU cooling fan /3 (FM13) Sensor cooling fan (FM16) Registration cooling fan (FM17) ADU drive board (ADUDB)
Remedy: 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. - 3 Replace the fan. - 4 Replace ADUDB.
Description: Suction cooling fan /2 (FM7) rotation abnormality + 24V power abnormality. The EM error detection signal of FM7 is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Suction cooling fan /2 (FM7) power abnormality. The EM error detection signal of FM7 is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Suction cooling fan /2 (FM7) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 3 Replace FM7 and ACDB at a time
Description: Suction cooling fan /2 (FM7) rotation abnormality. The EM error detection signal of FM7 is detected twice in succession within a specified period of time after FM7 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Suction cooling fan /2 (FM7) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM7. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Suction cooling fan /3 (FM8) rotation abnormality. When the print is started, the EM signal of FM8 turns ON.
Causes: Suction cooling fan /3 (FM8) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM8. - 5 Replace PRCB. - 6 Replace ACDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.