Code: C-0119

Description: The transfer belt cleaning motor (M5) speed abnormality. The M5EM error detection signal is detected twice in succession within a specified period of time after M5 was turned ON.
Causes: Transfer belt cleaning motor (M5) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 19-K 3 Replace M5. - 4 Replace PRCB.

Code: C-0120

Description: Paper exit conveyance motor (M31) speed abnormality. The M31EM error detection signal is detected twice in succession within a specified period of time after M31 was turned ON.
Causes: Paper exit conveyance motor (M31) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 22-K 3 Replace M31. - 4 Replace PRCB.

Code: C-0121

Description: Paper feed motor (M20) speed abnormality. The M20EM error detection signal is detected twice in succession within a specified period of time after M20 was turned ON.
Causes: Paper exit motor (M20) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 21-K 3 Replace M20. - 4 Replace PRCB.

Code: C-0130

Description: PF-703 coupling conveyance motor /1 (M4) power abnormality. An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON.
Causes: Coupling conveyance motor /1 (M4: PF-703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 20-L 3 Replace M4 and PFUDB at a time.

Code: C-0131

Description: PF-703 coupling conveyance motor /2 and /3 (M5 and M6) power abnormality. An error detection signal (blowout of ICP) of M5 and M6 is detected when M5 and M6 are turned ON.
Causes: Coupling conveyance motor /2 (M5: PF-703) Coupling conveyance motor /3 (M6: PF-703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 21-L 3 Replace PFUDB. - 4 Replace M5, M6 and PFUDB at a time.

Code: C-0132

Description: Abnormality of the power for the PF drive board (PFUDB) SD/CL of the 2nd tandem PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.
Causes: PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Check the drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/replace it if any abnormality, and then replace PFUDB. - 3 Replace PFUDB. - 4 If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time.

Code: C-0133

Description: 1st tandem PF-703 paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON.
Causes: Paper feed belt motor (M2: PF-703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 5-L 3 Replace M2. - 4 Replace PFUDB.

Code: C-0134

Description: 2nd tandem PF-703 paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON.
Causes: Paper feed belt motor (M2: PF-703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 5-L 3 Replace M2. - 4 Replace PFUDB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie