Description: Horizontal conveyance motor (M2) rotation abnormality. Rotation abnormality detected continuously for the specified time during M2 operation. 34-4
Causes: Horizontal conveyance motor (M2: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the horizontal conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 7-D 5 Replace M2. - 6 Replace SDDB. - 7 Replace SDCB.
Description: Folding entrance motor (M3) rotation abnormality. Rotation abnormality detected continuously for the specified time during M3 operation. 34-0/1/2/ 3
Causes: Folding entrance motor (M3: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the folding entrance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 9-D 5 Replace M3. - 6 Replace SDDB. - 7 Replace SDCB.
Description: Folding conveyance motor (M4) rotation abnormality. Rotation abnormality detected continuously for the specified time during M4 operation. 34-0/1/2/ 3
Causes: Folding conveyance motor (M4: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the folding conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 9-D 5 Replace M4. - 6 Replace SDDB. - 7 Replace SDCB.
Description: Bundle exit motor (M5) rotation abnormality. Rotation abnormality detected continuously for the specified time during M5 operation. 34-0/1/3
Causes: Bundle exit motor (M5: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the bundle exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-D 5 Replace M5. - 6 Replace SDDB. - 7 Replace SDCB.
Description: Folding sub scan alignment exit motor (M8) rotation abnormality. Rotation abnormality detected continuously for the specified time during M8 operation. 34-0/1/2/ 3
Causes: Folding sub scan alignment exit motor (M8: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the folding sub scan alignment exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 10-D 5 Replace M8. - 6 Replace SDDB. - 7 Replace SDCB.
Description: Paddle motor (M33) rotation abnormality. Rotation abnormality detected continuously for the specified time during M33 operation. 34-3
Causes: Trimmer paddle motor (M33: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the trimmer paddle, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDCB and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-W 4 Replace M33. - 5 Replace SDCB.
Description: Trimmer edge upper limit abnormality. The trimmer blade upper limit sensor (PS62) does not turn ON even after a specified period of time after the trimmer blade motor (M31) starts the home position search operation. 34-3
Causes: Trimmer completion sensor (PS62: SD-506) Trimmer blade motor (M31: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the trimmer blade upper limit, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 10-U 6 Replace PS62. - 7 Replace M31. - 8 Replace SDDB. - 9 Replace SDCB.
Remedy: 1 Check the wire slack, and repair the trimmer blade if any abnormality. - 2 Check the connector connection and the wiring between SDCB and the sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 10-U 4 Replace PS66. - 5 Replace SDCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.