Description: Thermistor /1 (TH1) high temperature abnormality (hardware). TH1 detects the fusing abnormality detection 1.
Causes: Fusing temperature sensor /1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 4.
Causes: Fusing temperature sensor /3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /1 (TH1) low temperature abnormality (software). TH1 does not get to 50°C when a specified period of time has elapsed after the main power switch (SW1) turns ON for the fusing ON control.
Causes: Fusing temperature sensor /1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /3 (TH3) low temperature abnormality (software). TH1 does not get to 50°C when a specified period of time has elapsed after the main power switch (SW1) turns ON for the fusing ON control.
Causes: Fusing temperature sensor /3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /1 (TH1) high temperature abnormality (long time/software). TH1 detects a temperature of 240°C or above 60 times in a period of 0.5second.
Causes: Fusing temperature sensor /1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /3 (TH3) high temperature abnormality (long time/software). TH3 detects a temperature of 220°C or above 30 times in a period of 1second.
Causes: Fusing temperature sensor /3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /1 (TH1) low temperature abnormality 1 (hardware). TH1 detects the fusing abnormality detection signal 2.
Causes: Fusing temperature sensor /1 (TH1) Fusing heater lamp /1 (L1) Fusing heater lamp /2 (L2) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing rollers /Up (L1 and L2), and clean/repair them if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L1/L2, and repair it if any abnormality. - 4 Check TH to see the installed position or distance to the fusing roller /Up, and adjust/ replace it if any abnormality. 14-F 5 Replace TH1. - 6 Replace L1 and L2. - 7 Replace PRCB. - 8 Replace ACDB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 5.
Causes: Fusing temperature sensor /3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.