Description: LPH fan /1 (FM3) rotation abnormality 1. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: LPH fan /1 (FM3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 4 Replace FM3 - 5 Replace PRCB. - 6 Replace ACDB.
Description: LPH fan /2 (FM25) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM25 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: LPH fan /2 (FM25) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: LPH fan /2 (FM25) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 3 Replace FM25 and ACDB.
Description: LPH fan /2 (FM25) rotation abnormality 2. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: LPH fan /2 (FM25) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM25. - 5 Replace PRCB. - 6 Replace ACDB.
Description: LPH fan /3 (FM26) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM26 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: LPH fan /3 (FM26) power abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: LPH fan /3 (FM26) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 3 Replace FM26 and ACDB.
Description: LPH fan /3 (FM26) rotation abnormality 3. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: LPH fan /3 (FM26) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM26. - 5 Replace PRCB. - 6 Replace ACDB.
Description: Front cooling fan (FM18) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM18 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.