Description: ISW write abnormality on PB. The firmware is not written on PB or an error is detected during the ROM check.
Causes: IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB)
Remedy: 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB.
Description: ISW write abnormality on GP. The firmware is not written on GP, or an error is detected during the ROM check.
Causes: IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB)
Remedy: 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB.
Description: ISW write abnormality on DF. When the main power switch (SW1) is ON, unwritten region by the ISW is detected in the DF control program.
Causes: DF control board (DFCB) Overall control board (OACB)
Remedy: 1 Check the connector connection and the wiring between the main body and DF, and repair it if any abnormality. - 2 Reinstalling DF firmware - 3 Replace DFCB - 4 Replace OACB.
Description: ISW write abnormality of controller. The firmware is not written on ICB or an error is detected during the ROM check.
Causes: IC board (ICB)
Remedy: 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Reinstall the firmware related to the controller. - 3 Replace ICB.
Description: JOB_RAM storage abnormality. The JOB information cannot be stored on the hard disk /1 (HDD1).
Causes: Hard disk /1 (HDD1) Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. 4-D 2 Reinstall the firmware related to the overall control. - 3 Replace HDD1.
Description: Hard disk /1 (HDD1) periodic cleaning abnormality. While in a periodical cleaning, opening the rote to hard disk is not succeeded.
Causes: Hard disk /1 (HDD1) Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. 4-D 2 Reinstall the firmware related to the overall control. - 3 Replace HDD1.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.