Description: Scanner cooling fan (FM19) rotation abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected.
Causes: Scanner cooling fan (FM19) Scanner drive board (SDB) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDB and PRCB, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-F 4 Replace FM19. - 5 Replace SDB. - 6 Replace PRCB.
Description: Filter coefficient abnormality. When processing images, a filter coefficient cannot be created normally.
Causes: Image processing board (IPB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB.
Description: Scanner FIFO abnormality. FIFO address abnormality for compression is indicated.
Causes: Image processing board (IPB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB.
Description: SVV length abnormality. After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time.
Causes: Image processing board (IPB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB.
Description: Scanner time out. • While in the image read, the compression processing from the scanner into the memory does not terminate within a specified period of time. • The development from the scanner into the page memory does not terminate within a specified period of time. • The SVV is not detected within a specified period of time.
Causes: Image processing board (IPB) Overall control board (OACB) Printer control board (PRCB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between IPB and OACB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between OACB and PRCB, and repair it if any abnormality. - 4 Replace IPB. - 5 Replace OACB. - 6 Replace PRCB.
Description: Compression device access abnormality. When writing images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made.
Causes: Image processing board (IPB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB.
Description: SVV off abnormality. While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started.
Causes: Image processing board (IPB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on IPB, and repair it if any abnormality. - 3 Rewrite the firmware for image control. - 4 Replace IPB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.