Description: Transfer suction fan (FM5) rotation abnormality + 24V power abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Transfer suction fan (FM5) power abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Transfer suction fan (FM5) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 3-L 3 Replace FM5 and ACDB at a time.
Description: Transfer suction fan (FM5) rotation abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Transfer suction fan (FM5) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 3-L 4 Replace FM5. - 5 Replace PRCB. - 6 Replace ACDB. -
Description: Paper exit cooling fan /Up (FM4) rotation abnormality + 24V power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Paper exit cooling fan /Up (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Paper exit cooling fan /Up (FM4) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 3 Replace FM4 and ACDB at a time.
Description: Paper exit cooling fan /Up (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, error detection signals (24V cut off/ICP blowout) are not detected.
Causes: Paper exit cooling fan /Up (FM4) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 4 Replace FM4 - 5 Replace PRCB. - 6 Replace ACDB.
Description: Paper exit cooling fan /Lw1 (FM10) rotation abnormality + 24V power abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.
Description: Paper exit cooling fan /Lw1 (FM10) power abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. In addition, 24V is normal, and an error detection signal (fuse blowout) is detected.
Causes: Paper exit cooling fan /Lw1 (FM10) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fun or I/O by hand, and repair it if any abnormality. 5-L 3 Replace FM10 and ACDB at a time.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.