Description: The rotation of the cooling fan /3 (FM6) is checked and +24V power source is also checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
Description: The blowout of ICP for the cooling fan /3 (FM6) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
Causes: Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
Description: Rotation of the cooling fan /3 (FM6) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of ICP) is not detected.
Causes: Confirmation of the wiring harness and the connector Cooling fan /3 (FM6) AC drive board (ACDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
Description: When the print is started, an error detection signal of the cooling fan /1 (FM26) or the cooling fan /2 (FM27) is detected.
Causes: Confirmation of the wiring harness and the connector Cooling fan /1 (FM26) Cooling fan /2 (FM27) AC drive board (ACDB) Printer control board (PRCB)
Description: An abnormal condition occurs with the FM10 EM signal a specified period of time after the ADU cooling fan /1 (FM10) is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector ADU cooling fan /1 (FM10) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
Description: Rotation of the ADU cooling fan / 1 (FM10) is checked. An abnormal condition occurs with the FM10 EM signal a specified period of time after FM10 is turned ON. This abnormal condition recurs even a specified period of time after FM10 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
Causes: Confirmation of the wiring harness and the connector ADU cooling fan /1 (FM10) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
Description: An abnormal condition occurs with the FM11 EM signal a specified period of time after the ADU cooling fan /2 (FM11) is turned ON. This abnormal condition recurs even a specified period of time after FM11 is turned OFF and then ON again, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector ADU cooling fan /2 (FM11) ADU drive board (ADUDB) DC power supply /2 (DCPS2)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.