Mã lỗi Konica-Minolta bizhub Pro 950 — Trang 28/35

Code: C-6706

Description: While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started.
Causes: Confirmation of the wiring harness and the connector Overall control board (OACB)

Code: C-6707

Description: Shading correction abnormality (GA abnormality).
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)

Code: C-6708

Description: AOC/AGC adjustment abnormality. The light blocking cover at the read section and the lens cover are removed. • The connector of the CCD board is disconnected. • The power cable of the CCD board is unplugged. • The ICP of the CCD board is cut off. The light volume of the exposure lamp is excessive. The exposure lamp does not light up.
Causes: 1. CCD related parts Confirmation of the wiring harness and the connector CCD board (CCDB) Overall control board (OACB) 2. Exposure lamp related parts Confirmation of the wiring harness and the connector Exposure lamp (L4) L4 inverter (L4INVB) Scanner drive board (SDB)

Code: C-6709#

Description: The adjustment data evacuated by resolutions is not available.
Causes: Confirmation of the wiring harness and the connector Overall control board (OACB)

Code: C-6710#

Description: A density conversion gamma curve cannot be created normally.
Causes: Confirmation of the wiring harness and the connector Overall control board (OACB)

Code: C-6711

Description: Calibration start abnormality.
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)

Code: C-6712

Description: Calibration completion abnormality.
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)

Code: C-6713

Description: Despite of the MPC not being terminated, the initial sampling of the APC is attempted.
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)