Code: C-5330

Description: The rotation of the power supply cooling fan /3 (FM32) is checked. An abnormal condition occurs with the FM32 EM signal a specified period of time after FM32 is turned ON. This abnormal condition recurs even a specified period of time after FM32 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
Causes: Confirmation of the wiring harness and the connector Power supply cooling fan /3 (FM32) DC power supply /2 (DCPS2)

Code: C-6101

Description: The scanner home sensor (PS5) does not turn ON within a specified period of time after the home position search is started.
Causes: Confirmation of the wiring harness and the connector Scanner motor (M13) Scanner home sensor (PS5) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2)

Code: C-6301

Description: The rotation of the scanner cooling fan (FM7) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM7 EM signal a specified period of time after FM7 turns ON. This abnormal condition recurs even a specified period of time after FM7 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector Scanner cooling fan (FM7) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2)

Code: C-6701

Description: When processing images, a filter coefficient cannot be created normally.
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)

Code: C-6702

Description: FIFO address abnormality for the scanner. While in the image read, the compression of image data that is read in is not correctly terminated.
Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged)

Code: C-6703

Description: After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time.
Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged)

Code: C-6704

Description: While in the image read, the compression processing from the scanner into the memory does not terminate within a specified period of time. The development from the scanner into the page memory does not terminate within a specified period of time. The SVV is not detected within a specified period of time.
Causes: Confirming the DF operation Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB)

Code: C-6705

Description: When reading images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made.
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie