Description: The rotation of the power supply cooling fan /3 (FM32) is checked. An abnormal condition occurs with the FM32 EM signal a specified period of time after FM32 is turned ON. This abnormal condition recurs even a specified period of time after FM32 is turned OFF and then ON again, and an error detection signal (24V cut off) is not detected.
Causes: Confirmation of the wiring harness and the connector Power supply cooling fan /3 (FM32) DC power supply /2 (DCPS2)
Code: C-6101
Description: The scanner home sensor (PS5) does not turn ON within a specified period of time after the home position search is started.
Causes: Confirmation of the wiring harness and the connector Scanner motor (M13) Scanner home sensor (PS5) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
Code: C-6301
Description: The rotation of the scanner cooling fan (FM7) is checked, and 24V power source is also checked. An abnormal condition occurs with the FM7 EM signal a specified period of time after FM7 turns ON. This abnormal condition recurs even a specified period of time after FM7 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: Confirmation of the wiring harness and the connector Scanner cooling fan (FM7) Scanner drive board (SDB) Printer control board (PRCB) DC power supply /2 (DCPS2)
Code: C-6701
Description: When processing images, a filter coefficient cannot be created normally.
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB)
Code: C-6702
Description: FIFO address abnormality for the scanner. While in the image read, the compression of image data that is read in is not correctly terminated.
Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged)
Code: C-6703
Description: After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time.
Causes: Confirmation of the wiring harness and the connector Overall control board (OACB) (Gate array damaged)
Code: C-6704
Description: While in the image read, the compression processing from the scanner into the memory does not terminate within a specified period of time. The development from the scanner into the page memory does not terminate within a specified period of time. The SVV is not detected within a specified period of time.
Causes: Confirming the DF operation Confirmation of the wiring harness and the connector Overall control board (OACB) Printer control board (PRCB)
Code: C-6705
Description: When reading images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made.
Causes: Confirmation of the wiring harness and the connector Reinstalling firmware Overall control board (OACB