Code: C-C106

Description: While in the data transmission by the ISW, a formal header information cannot be received within a specified period of time.
Causes: USB cable USB port on PC

Code: C-C107

Description: While in the data transmission by the ISW, a checksum error or header error is detected with the download data.
Causes: USB cable Program file corruption

Code: C-C108

Description: When ISW transfers data, the data is not written into the flash ROM correctly.
Causes: USB cable The board to which the data is transferred.

Code: C-C109

Description: When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the FS control program.
Causes: FS control program

Code: C-C117

Description: When turning the sub power switch (SW2) ON, ISW unwritten area in the GP program was detected.
Causes: GP control firmware

Code: C-C119

Description: When turning the sub power switch (SW2) ON, ISW unwritten area in the MK program was detected.
Causes: I/F board (IFB)

Code: C-C120

Description: When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the DF control program.
Causes: Confirmation of the wiring harness and the connector DF control board (DFCB: DF) Overall control board (OACB: main body)

Code: C-C125

Description: When the main power switch (SW1) is ON, a region into which no write was made by the ISW is detected in the IC program.
Causes: IC program