Description: Main Motor Failure
• The Transport Motor Lock signal remains set to H for a set period of time while the Transport Motor is turning.
Remedy: 1 Check the M2 connector for proper connection, and correct as necessary 2 Check the M2 for proper drive coupling, and correct as necessary. 3 M2 operation check. 4 Replace PWB-A. 5 Replace PU1.
Code: C0010
Description: Imaging Unit Motor Failure
• The Imaging Unit Motor Lock signal remains set to H for a set period of time while the Imaging Unit Motor is turning. • The Imaging Unit Motor Lock signal remains set to L for a set period of time while the Imaging Unit Motor remains stopped.
Remedy: 1 Check the M1 connector for proper connection, and correct as necessary. 2 Check the M1 for proper drive coupling, and correct as necessary 3 M1 operation check. 4 Replace PWB-A. 5 Replace PU1.
Code: C0044
Description: EDH Fan Motor Failure
• Refer to the Service Manual for the relevant option.
Remedy:
Code: C0045
Description: Cooling Fan Failure
• The Cooling Fan Motor Lock signal remains set to H for a set period of time while the Cooling Fan Motor is turning. • The Cooling Fan Motor Lock signal remains set to L for a set period of time while the Cooling Fan Motor remains stopped.
Remedy: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M5 operation check. 4 Replace PWB-A.
Code: C004E
Description: Power Unit Cooling Fan Failure
• The Power Unit Cooling Fan Motor Lock signal remains set to H for a set period of time while the Power Unit Cooling Fan Motor is turning. • The Power Unit Cooling Fan Motor Lock signal remains set to L for a set period of time while the Power Unit Cooling Fan Motor remains stopped.
Remedy: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M4 operation check. 4 Replace PWB-A.
Code: C004F
Description: IU Cooling Fan Failure
• The I/U Cooling Fan Motor Lock signal remains set to H for a set period of time while the I/U Cooling Fan Motor is turning. • The I/U Cooling Fan Motor Lock signal remains set to L for a set period of time while the I/U Cooling Fan Motor remains stopped.
Remedy: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M6 operation check. 4 Replace PWB-A.
Code: C0214
Description: Abnormal Image Transfer Voltage
• The image transfer voltage exceeds 100 V for the set period of time while the Imaging Unit Motor remains stopped.
Remedy: 1 Check the installation of the Image Transfer Roller. 2 Replace TH1.
Code: C0500
Description: Fusing Warm-Up Failure (Main)
• The Fusing Roller Thermistor does not detect the required temperature within 30 sec. after a warm-up cycle has begun; therefore, the copier does not complete the warm-up cycle. • The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle.
Remedy: 1 Check that the Fusing Roller Heater Lamp comes on when the Power Switch is set to ON, and correct or replace as necessary. 2 Check that the Fusing Roller Sub Heater Lamp comes on when the Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the Fusing Roller Thermistor and the Fusing Roller Sub Thermistor, and correct or clean as necessary. 4 Check the operation of the Fusing Roller Thermistor. Remove CN80 (4P), and then check that the resistance across CN80-2 and - 3 on the Thermistor is infinity. 5 Check the operation of the Fusing Roller Sub Thermistor. Remove CN81 (4P), and then check that the resistance across CN81-2 and - 3 on the Thermistor is infinity. 6 Check the continuity of the Fusing Roller Heater Lamp. Correct or replace as necessary. 7 Check the continuity of the Fusing Roller Sub Heater Lamp. Correct or replace as necessary. 8 Replace PU1. 9 Replace PWB-A.