Mã lỗi Konica-Minolta Di552 — Trang 14/15
Code:
Tất cả lỗi (113)
C0000
C0010
C0040
C0042
C0044
C0045
C0046
C0047
C0049
C004C
C004E
C004F
C0072
C0090
C0210
C0400
C0420
C0500
C0510
C0520
C0540
C0602
C0650
C0900
C0904
C0910
C0914
C0920
C0924
C0950
C0954
C0990
C0994
C0996
C0997
C0998
C099C
C09C0
C0B00
C0B02
C0B03
C0B04
C0B20
C0B21
C0B24
C0B30
C0B31
C0B34
C0B35
C0B36
C0B38
C0B48
C0B49
C0B4A
C0B4B
C0B4D
C0B4E
C0B4F
C0B50
C0B51
C0B54
C0B73
C0B74
C0B78
C0B80
C0BA0
C0BA1
C0BA2
C0BC0
C0BC1
C0BC2
C0BC3
C0BF0
C0D50
C0E00
C0F24
C0F32
C0F33
C12CX
C1300
C1326
C1330
C1334
C133B
C13F1
C13F4
C13F5
C13F6
C13F7
C13F8
C13F9
C13FA
C13FC
C1401
C1402
C1410
C1426
C1428
C1429
C142A
C1430
C143E
C1440
C1441
C1450
C1461
C1462
C1470
C1471
C1472
C1499
C18XX
C1XXX
Description: Sequence trouble timeout
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, check the cables, timing belt, and other drive transmission mechanism from the Scanner Motor to the Scanner. 3. If step 2 has been checked okay, change Image Processing Board.
Description: Serial GA1 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Description: Serial GA2 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Description: Module-to-module communication (CCM-EVM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Description: Module-to-module communication (EVM-SQM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Description: Module-to-module communication (EVM-AMM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Description: IR cooling fan malfunction
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, check CN152 of IR Cooling Fan Motor and PJ4IC of SCP Board for proper connection. 3. If the connections are okay, change motor or SCP Board.
Description: SCSI communications unit failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.