Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, check the cables, timing belt, and other drive transmission mechanism from the Scanner Motor to the Scanner. 3. If step 2 has been checked okay, change Image Processing Board.
Code: C1461
Description: Serial GA1 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Code: C1462
Description: Serial GA2 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Code: C1470
Description: Module-to-module communication (CCM-EVM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Code: C1471
Description: Module-to-module communication (EVM-SQM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Code: C1472
Description: Module-to-module communication (EVM-AMM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Code: C1499
Description: IR cooling fan malfunction
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, check CN152 of IR Cooling Fan Motor and PJ4IC of SCP Board for proper connection. 3. If the connections are okay, change motor or SCP Board.
Code: C18XX
Description: SCSI communications unit failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.