Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta Di552 — Trang 13/15

Code: C1426

Description: Report retransmitted
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change the Image Processing Board.

Code: C1428

Description: Transmission buffer full
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change the Image Processing Board.

Code: C1429

Description: Reception buffer full
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change the Image Processing Board.

Code: C142A

Description: Transmission hard error
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change the Image Processing Board.

Code: C1430

Description: H-Sync error
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change the Image Processing Board.

Code: C143E

Description: EDH malfunction
Remedy:

Code: C1440

Description: Gain adjustment failure
Remedy: 1. Reset the malfunction. 2. Check that the Original Glass is properly installed. 3. Check the optical system. 4. If the optical system has been checked okay, change Memory Board.

Code: C1441

Description: CCD failure (clamp adjustment failure)
Remedy: 1. Reset the malfunction. 2. Check that the Original Glass is properly installed. 3. Check for extraneous light and check to see if the CCD Assy and mirrors are installed at the correct positions. 4. If the same malfunction is detected again, change Image Processing Board.