Description: Color PC drum motor malfunction
• The color PC drum motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the color PC drum motor is being rotated.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M2 operation check MFPB PJ11MFPB-8 to 14 J-2. 5 Change M2. 6 Change MFPB. 7 Change DCPU.
Description: Transport motor malfunction
• The transport motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the transport motor is being rotated.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check M3 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M3 operation check MFPB PJ11MFPB-1 to 7 J-3. 5 Change M3. 6 Change MFPB. 7 Change DCPU.
Description: K developing motor malfunction
• The K developing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the K developing motor is being rotated.
Remedy: 1 Check the M5 connector for proper connection and correct as necessary. 2 Check M5 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M5 operation check MFPB PJ8MFPB-8 to 14 J-4. 5 Change M5. 6 Change MFPB. 7 Change DCPU.
Description: Color developing motor malfunction
• The color developing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the color developing motor is being rotated.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the MFPB connector for proper connection and correct as necessary. 3 M1 operation check. 4 Change driving unit. 5 Change MFPB. 6 Change DCPU.
Description: Fusing fan motor malfunction
• The fusing fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the fusing fan motor is being rotated.
Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM2 operation check MFPB PJ21MFPB-3 (LOCK) C-10. 4 Change FM2. 5 Change MFPB.
Description: Duplex cooling fan motor malfunction
• The duplex cooling fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the duplex cooling fan motor is being rotated.
Remedy: 1 Check the FM4 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check MFPB PJ27MFPB-6 (LOCK) C-2 4 Change FM4. 5 Change MFPB.
Description: Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
Remedy: 1 Check the FM3 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check MFPB PJ31MFPB-3 (LOCK) C-11. 4 Change FM3. 5 Change MFPB.
Description: DC power supply fan motor malfunction
• The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated.
Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check MFPB PJ9MFPB-3 (LOCK) C-10 to 11. 4 Change FM1. 5 Change MFPB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.